My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10721 19TH AVE SE 2023-04-07
>
Address Records
>
19TH AVE SE
>
10721
>
10721 19TH AVE SE 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:36:50 PM
Creation date
4/7/2023 2:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10721
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin,Commercial Plans Examiner—Public Services Department <br /> RE:Plan Check#C 1802-019— 10725 19th Avenue SE—Correction Notice#2 <br /> October : 2018 <br /> 'age <br /> ii. Verify if cantilever reinforcement is required. Revise Detail 9/S4.2 as needed. <br /> iii. The dead line load, based on a tributary wall height of 11 feet and a tributary roof width <br /> of 7 feet, appears to be at least 260 plf based on the weight on calculation page A-5. The <br /> line load on page B-8 is only 108.5 plf and should be increased. <br /> iv. The snow line load, based on a tributary roof width of 7 feet, appears to be at least 175 <br /> plf. The line load on page B-8 is only 152.5 plf and should be increased. <br /> v. The joist partially relies on loads on the back-span portion for stability. The joists should <br /> be evaluated with reduced dead loads on the back-span(i.e.,0.6D). Full live loads should <br /> be placed on the cantilever only(i.e., no live load on the back-span). <br /> vi. Calculations substantiating the hold-down capacity of the hangers at the back-span end <br /> should be provided where required to stabilize the joists. <br /> b. The following comments should be addressed for the beam: <br /> i. The design assumes that the joists carry all of the gravity loading. However,depending <br /> on the relative stiffnesses of the framing,the beam will deflect and support a portion of <br /> the gravity weight. A portion of the gravity loading should be including in the beam <br /> loading. <br /> ii. The beam should include vertical seismic load effects per ASCE 7-10 Sections 12.4.2.2 <br /> and 12.4.3.2. <br /> iii. Calculations substantiating the capacity of the hangers shall be submitted for review. The <br /> hangers shall be able to resist loads in both directions. <br /> iv. The beams are supported by cantilever B2 beams. Calculations substantiating the load <br /> path should be submitted for review,including but not limited to: beams, posts at the <br /> cantilever base,and back-span resistance. <br /> a. i. The joists can cantilever more than 24"per general note on page 11 of the Trus Joist TJI <br /> Joist Specifier's Guide below the cantilevers table by using Forte software.Attached forte <br /> calculation sheets S-2 and S-3 show the joists pass design. <br /> ii.No cantilever reinforcement is required but web stiffeners are provided at the cantilever <br /> support. <br /> iii.-iv. See joist calculation sheet S-2 for updated design loads. <br /> v. See attached joist calculation S-3 showing the reduced load on backspan. <br /> vi. The maximum uplift force at the back span of the joist is 336 pounds. Upside down <br /> IUS2.06 hangers are called out on detail 9/S4.2and have a capacity of 1,070 pounds of <br /> uplift. <br /> b. i. See attached sheet S-4 for the gravity weight applied to the rim beam. <br /> ii. The worst case uplift occurs with no dead load applied to the beam, which is analyzed on <br /> sheet S-6. The worst case moment and shear occurs with full dead load which is analyzed <br /> on sheet S-5. <br /> iii. See attached sheet S-4 for hanger check of the rim beam. <br /> iv. See attached sheets S-7 and S-8 for cantilever beam designs. The plans have been <br /> updated to follow uplift load path where required. See sheet S-9 for updated footing <br /> calculations at these locations. <br /> Lateral System: <br /> 15. This comment has not been completely addressed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.