My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1708 25TH ST A B 2023-04-07
>
Address Records
>
25TH ST
>
1708
>
1708 25TH ST A B 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:07:46 PM
Creation date
4/7/2023 3:06:50 PM
Metadata
Fields
Template:
Address Document
Street Name
25TH ST
Street Number
1708
Unit
A B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br /> 4" oc are being used on this project. Per IBC 1705.12.2, special inspections would be <br /> required for this wall construction. <br /> 22. It appears that the lateral design of the structure is using the Simplified Procedure to obtain <br /> forces for the seismic design of lateral force resisting elements. Use of the Simplified <br /> Procedure would require the use of ASCE 7-10 Table 12.14-1 to categorize the proposed <br /> seismic force resisting system. Please revise as required. For example, it appears from the <br /> permit calculations, that the concrete column members intended to be part of the lateral <br /> force resisting system are acting as a cantilever columns rather than as a portal frame <br /> system. Per ASCE 7-10 12.14.1.1, the Simplified Procedure for seismic design, cantilever <br /> column systems are not covered under the table. <br /> 23. It appears that use of the Simplified Procedure cannot be applied to this proposed structure <br /> as it appears that an in-plane irregularity such as discontinuous shear walls occurs on Sheet <br /> 5 between the Middle Floor and the Lower Floor Level per ASCE 7-10 Sec 12.14.1.1 Item 11. <br /> The T-1 holddowns are developing into the glulam beams which do not stack with a shear <br /> wall below. Please clarify the design or revise the analysis as required. <br /> 24. If a cantilever column system is intended to be used for the lateral resistance of the <br /> structure, then the analysis procedure as required by ASCE 7-10 Sec 12.6 would be required <br /> to be implemented in the force determination over the currently used Simplified Procedure. <br /> Also, the following items would need to be addressed: <br /> a. Cantilever columns used for lateral resistance are required to adhere to the special <br /> design and detailing requirements in ACI 318-14 Sec 18.7. Requirements such as <br /> minimum column dimensions, tie spacing, shear capacity of the column do not appear <br /> to meeting these criteria as shown on Details 1A and 2A on Sheet 3 of the permit <br /> drawings. <br /> b. It appears that the glulam beams, are intended to transfer lateral forces into the <br /> concrete columns, which would also indicate the glulams and their connections would <br /> be required to be designed with the overstrength factors included per ASCE 7-10 Sec <br /> 12.3.3.3. <br /> 25. On the Shear Transfer Detail of Sheet 7, a note that indicates "If wall above is 350 plf or <br /> greater, A35 anchors to tie the rim to the mudsill." Currently, shear wall schedules do not <br /> appear to indicate capacities nor demands on the drawings to determine when this <br /> connection is to be used. Please identify these locations on the drawings or provide a means <br /> for the contractor or builder to obtain these loads/capacities in order to determine where this <br /> condition occurs on the project. IBC 107.2.1 and 1603.1.8. <br /> 26. On Sheet 2 of the drawings, there appear to be two call outs of design live loads on the <br /> notes. One set under "Building" and another under "Lumber Strength." Under the "Building" <br /> heading, the deck design live loads are to be 1.5 times the occupancy served per WAC <br /> Amendment to IBC Table 1607.1. It appears under the "Lumber Strength" heading, that the <br /> deck design live load is shown to be 40 psf. Please revise the notes as required for code <br /> consistency. <br /> 27. On Sheet 8, it appears that the roof to shear wall transfer details do not supply plywood <br /> sheathing to transfer the roof diaphragm loads to the shear walls. Please clarify if sheathing <br /> Page 3of4 <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.