My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023/04/19 Council Agenda Packet
>
Council Agenda Packets
>
2023
>
2023/04/19 Council Agenda Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2023 9:00:24 AM
Creation date
4/20/2023 9:21:40 AM
Metadata
Fields
Template:
Council Agenda Packet
Date
4/19/2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT A-1 <br />SCOPE OF WORK <br />GEOTECHNICAL ENGINEERING SERVICES <br />CITY OF EVERETT, WATER MAIN REPLACEMENT Y <br />GEOENGINEERS JOB NO. 0661-137-00 <br />INTRODUCTION AND PROJECT UNDERSTANDING <br />GeoEngineers, Inc. is pleased to present our scope and fee estimate for geotechnical engineering services <br />for the proposed Water Main Y project located in Everett, Washington. We understand the City is proposing <br />to upgrade 5 segments of existing 6- to 8-inch diameter water main, bundled together as Water Main <br />Replacement "Y". The proposed segments to be replaced are listed below: <br />1. Beverly Lane (74th Street SE to 76th Street SE). Replace approximately 920 LF of existing 8-inch <br />diameter asbestos cement pipe with new 8-inch diameter ductile iron water main. <br />2. 75th Street SE and Evergreen Way Intersection. Replace approximately 110 LF of existing 8-inch <br />diameter asbestos cement pipe with new 8-inch diameter ductile iron water main. <br />3. Evergreen Way (south of 52nd Street SE). Replace and upsize approximately 525 LF of existing 6- <br />inch diameter asbestos cement pipe with 8-inch diameter ductile iron water main. <br />4. Interstate 5 bridge (E. Grand Ave. to 4th Street SE). Replace and upsize approximately 800 LF of existing <br />8-inch diameter ductile iron pipe suspended on 1-5 bridge with new 12-inch diameter ductile iron water main. <br />5. Madrona Avenue (W. Mukilteo Blvd to SeahurstAve.). Replace and upsize approximately 2,200 LF of existing <br />6-inch diameter cast iron pipe with new 8-inch diameter ductile iron water main. <br />Geotechnical engineering services are requested for Sites 1 through 3 and Site 5 to evaluate subsurface <br />soil and groundwater conditions and provide geotechnical recommendations for design. Key geotechnical <br />considerations will include trenching and excavation, temporary slopes and temporary shoring, construction <br />dewatering, pipe support, reuse of on -site soils, and geologic hazards and excavation stability. <br />SCOPE OF SERVICES <br />Based on our discussions with the design team, review of the exhibits, and brief site visits, we anticipate <br />our scope will include the following tasks: <br />A. REVIEW AVAILABLE GEOLOGIC AND SUBSURFACE INFORMATION <br />Review geologic maps, soil surveys, and available geotechnical reports in our files and on public <br />data bases regarding subsurface soil and groundwater conditions in the vicinity of the sites. <br />
The URL can be used to link to this page
Your browser does not support the video tag.