Laserfiche WebLink
I <br /> 1 <br /> 2 GLF 8-20.4.DOCX <br /> 3 8-20.4 Measurement <br /> 4 <br /> 5 Section 8-20.4 is supplemented with the following: <br /> 6 <br /> 7 (******) I <br /> 8 "Vehicle Loop Detectors", for both loop perimeter and home run, shall be measured by <br /> 9 the linear foot of the neat sawcut line in place in the roadway. No additional measurement <br /> 10 will be made for the installation of lead-in conduit and shall be included in the I <br /> 11 measurement <br /> 12 <br /> 13 "Loop Detector Lead-In Cable" shall be measured by the linear foot of the neat line of 1 <br /> 14 conduit between the controller cabinet and loop splice. No additional measurement will <br /> 15 be made for coiled loop detector cable in junction boxes or cabinets. <br /> 16 I 17 "Conduit Pipe 2 In. Diam." shall be measured by the linear foot of the neat line of conduit <br /> 18 between the junction box and the curb line. No additional measurement will be made for <br /> 19 sweeps or elbows in junction boxes or at the curb line. <br /> 20 <br /> 21 GLF 8-20.5.DOCX <br /> 22 8-20.5 Payment <br /> 23 I 24 Section 8-20.5 is supplemented with the following: <br /> 25 <br /> 26 (******) 111 <br /> 27 "Vehicle Loop Detectors," per linear foot. <br /> 28 1 29 The unit contract price shall include saw cutting, cleaning and drying of pavement, <br /> 30 installing loops and home runs, loop lead-in conduits, loop wire, sealant, splice kit and <br /> 31 splicing between loop wire and lead-on cable, any work necessary to access a junction <br /> 32 box and testing of the vehicle detectors as defined in Section 8-20.3(14)D. <br /> 33 <br /> 34 No payment shall be made for any loops that are not spliced and fully operational, <br /> 35 including any loop detector lead in cable required to make the loop operational. <br /> 36 <br /> 37 "Loop Detector Lead-In Cable", per linear foot. <br /> 38 <br /> 39 The unit contract price shall be full pay for furnishing and installing each loop detector <br /> 40 lead-In cable in existing conduits between the traffic signal control cabinet and loop splice <br /> 41 point, including all and all other Work necessary terminate loop lead in cable at either end. <br /> 42 <br /> 43 No payment shall be made for any detector lead-in cable that is not spliced and fully <br /> 44 operational, including any testing required to make the loop operational. I <br /> 45 <br /> 46 "Conduit Pipe 2 In. Diam.", per linear foot. <br /> 47 The unit contract price shall be full pay as described in this Section for furnishing and <br /> 48 installing each conduit stub-out where shown in the Plans, including furnishing all conduit, <br /> i <br /> 2023 FEDERAL OVERLAY <br /> FEDERAL AID#STBGUL-2715(011) <br /> WO#3788 March 2,2023 SP-106 <br />