Laserfiche WebLink
• • <br /> house does not include existing space in the attic; these room appears to have been <br /> construction without permits. In addition, Section 1/A.301 does not appear to show that the <br /> attic has sufficient head clearance to be used as habitable space. The proposed room <br /> cannot be converted as proposed. The space may be used for storage, but the creation of <br /> the room must be shown as new construction and substantiated in the current proposed <br /> drawings for this use. <br /> The Attic will be kept as storage and I will address the alterations of it with the 2018 WA State Energy Code. <br /> 1. The drawings show construction of new staircases in the original house. The following <br /> comments should be addressed: <br /> a. Additional framing requirements appear to be required. <br /> b. The stairway does not appear to have adequate head clearance, particularly at the <br /> winder portions. The clearance shown does not dimension the walk-line as required. <br /> c. Additional sections should be shown to demonstrate the required structural <br /> construction and clearances. Portions of the stairs should be cut-away to clearly <br /> demonstrate clearances. <br /> d. The walkline should be shown and dimensions provided to demonstrate compliance. <br /> / will address this in an extra page. <br /> Review of your project will be performed in the order received once the required documentation has <br /> been submitted. Please let me know if you have questions. <br /> If/resubmit again do I need to resubmit all the Engineering sets and Calcs ? or can you just keep the previous <br /> ones. Since I have already dropped off the same set of engineering twice, so that's 4 sets, besides being extra <br /> cost I want to minimize paper that goes straight into the trash. <br /> Please let me know if there's anything else /need to address before making changes and dropping off a <br /> couple of new Set of Architectural Plans. Thanks in advance, <br /> Robert Smith Mac Donald <br /> A.I.A.Associate, M.R.E.D. <br /> 905 130th NE Ave <br /> Bellevue, WA, 98005 <br /> Office 425-341-3720 <br /> Fax 425-977-0670 <br /> Cell 210-897-3694 <br /> robmac50.rs@gmail.com <br /> http://www.eastsidedesignstudiO.COM <br /> 4/� <br />