Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 3 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C405.2.4 Daylight responsive Indicate on plans lighting zone(s)served by <br /> controls daylight responsive controls;indicate that the <br /> area served by each control device does not <br /> exceeds 2,500 sf <br /> NA Identify sidelit and toplit daylight zones that <br /> are not provided with daylight sensing <br /> controls and the exception(s)that apply <br /> NA C405.2.4.1.1 Daylight responsive Indicate on plans the lighting load reduction <br /> controls method(continuous dimming,or stepped <br /> dimming that provides at least two even steps <br /> between 0%-100%of rated power) <br /> NA C405.2.4.1 Daylight responsive Indicate that daylight sensing controls are <br /> controls configured to completely shut off all <br /> controlled lights in the lighting zone <br /> YES C405.2.5 Additional controls- Identify spaces and lighting fixtures on plans Elec Sheets <br /> Specific application that require specific application lighting <br /> lighting controls controls per this section <br /> YES C405.2.5, Display and accent Indicate on plans that manual controls are Elec Sheets <br /> Item 1 lighting provided that control display,accent lighting <br /> and display case lighting independently from <br /> both general area lighting and other lighting <br /> applications within the same space <br /> YES Indicate manual and automatic(occupant Elec Sheets <br /> sensor or time switch)lighting control <br /> methods <br /> C405.2.5, Hotel/motel_nest, ' Indicate method of automatic control- <br /> Item 3 rooms vacancy,or captive key control of all installed <br /> luminaires and switched receptacles in guest <br /> room <br /> NA C405.2.5, Supplemental task Indicate method and location of manual and <br /> Item 1 lighting automatic shut-off control(occupant sensor or <br /> time switch)for supplemental task lighting, <br /> including under-shelf or under-cabinet <br /> lighting <br /> YES C405.2.5, Lighting equipment Indicate on plans that lighting equipment for Elec Sheets <br /> Item 1 for sale or sale or demonstration are controlled <br /> demonstration independently from both general area lighting <br /> and other lighting applications within the <br /> same space <br /> YES Indicate manual and automatic(occupant Elec Sheets <br /> sensor or time switch)lighting control <br /> methods <br /> NA C405.2.5, Lighting for non- Identify all eligible non-visual lighting <br /> Item 4 visual applications applications on plans;indicate that the area <br /> served by each control device does not <br /> exceeds 4,000 sf <br /> NA Indicate on plans that non-visual lighting are <br /> controlled independently from both general <br /> area lighting and other lighting applications <br /> within the same space <br /> ( Page 3/10 <br />