Laserfiche WebLink
! i <br /> • 11.The sales prohibition covenant must be on file with Snohomish County prior to issuance of <br /> the building permit.Please forward a copy of the recorded document when completed. <br /> RCW 64.55 Response: The Owner has been notified of this requirement. . <br /> Construction <br /> 1. The parapet details on the A-8.xx sheets should be completed (tags show#DrgID/#LayID). <br /> Fire rated parapets are required per Section 705.11 on several exterior walls due to <br /> distances to property lines (or Exception 4 may be employed).Response: See revised A-8.0 <br /> series sheets.Tag text layers are turned on. Exception allowing elimination of parapets with <br /> gyp'board to terminating under the roof deck and prohibition of roof openings within 5' of the <br /> exterior wall is proposed. <br /> 2. Is the listing for wall type W-5/A-9.1 WP 3371 or WP 3380 (we are not on the most current <br /> GA Manual)? Please provide a cut sheet.Response: GA 3371 is from 21 s`edition GA 600 <br /> 2015. See attached GA 3371 page and book cover. <br /> 3. The printing for wall type M-1-4/A-9.0 was cut off on the top.The detail,listing and fire <br /> resistance will be review on the re-check.Response: See revised Sheet A-9.0 <br /> 4. Is the listing for roof/ceiling type FW-5/A-9.1 FC 5530 as shown? If so,please provide a cut <br /> sheet.Response: Listing is as shown. See attached cut sheet for assembly FC 5530. <br /> 5. Floor/ceiling assembly FW-6/A-9.1 requires proprietary gypsum floor topping,Levelrock <br /> brand floor underlayment and Type C GWB per listing GA File No.FC 5011.Response: <br /> Link to the USG Design page is as follows: <br /> https://www.usgdesignstudio.com/assembly.asp?id=954115&assemblyCategory=921054) It <br /> allows for alternate gyperete manufacture and 5/8" gyp'bd (USG sheetrock brand) <br /> 6. Two-hour wall type C-1-7 is shown for the stair enclosures on PL 2 and the ls`floor and the <br /> elevator shaft on the 2"d floor,however the wall type is not provided on the A-9.x sheets. <br /> Response: See revised Sheet A-9.0 for added wall type. <br /> 7. The wall callout M-1-5 for the trash chute detail on Sheet A-10.2 should be revised to a two- <br /> hour wall type.Section 713.4 Response: The wall tag at this location has been revised to wall <br /> type M-1-6. See detail # 18 sheet A 10.2 <br /> 8. The trash room should be shown surrounded by minimum two-hour walls and 90-minute <br /> openings (including the coiling door).Section 713.13.4 Response: Wall tag is for a fully <br /> grouted CMU wall (4 hour... greater than required) and door schedule has been revised to show <br /> 90min doors. <br /> 9. Please provide a detail showing the continuous two-hour shaft construction (elevators, <br /> stairs,mechanical) per Section 707.5: <br /> a. Through or abutting a one-hour floor/ceiling assembly. <br />