My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Mr. Art Skotdal <br /> Skotdal Real Estate <br /> Plan Check Number: B1906-031, First Building Review - Structural <br /> August 26, 2019 <br /> b. Continuing with the previous comment, the structural calculations indicate slab thicknesses <br /> varying from 11 to 20 inches with steps up to 6 inches. The design shall be revised as <br /> needed pending the determination of the correct slab thicknesses and step heights. <br /> c. The architectural and structural plans do not consistently show openings in the floor slab. <br /> Similarly, the structural calculations are not consistent with either the architectural or <br /> structural plans. The structural design shall be revised. <br /> d. The structural calculations include a 150 psf live load. The unreduced live load should be <br /> 200 psf based on five levels at 40 psf for each level. Documentation substantiating the <br /> value shall be submitted for review. <br /> e. The design shall include a snow load of 25 psf. See Section 01003 "Design Live Loads / <br /> Data"in the Structural Notes on sheet S1.01. <br /> f. The design shall consider the load combinations per ASCE 7-10 Section 12.4.2.3 including <br /> the vertical seismic load effects per Section 12.4.2.2. <br /> g. The PT-tendons on Sheet S2.08 do not include number and depths of the tendons. Note <br /> that the tendons are not shown consistently with the standards used on the other PT-slab <br /> plans. The plan shall be revised. <br /> h. Sheet S2.09 provides specifications for the mild reinforcement. It is anticipated that the <br /> reinforcement will be revised pending updates to the calculations based on comments <br /> above. Details for the steps in the slab should be included. Note that the column at Grid <br /> G/7 does not include references for the reinforcement. The plan shall be revised. <br /> 27.The Level 2 post-tensioned (PT) slab on Sheet S2.08 includes a cantilever balcony project from <br /> the slab edge at Grid B/3-6.4. See IBC Sections 107.2.1, 1603.1, 1604.1, and 1604.4. A <br /> canopy appears to be located below and supported by the balcony per Section 1/A-8.0. The <br /> following comments shall be addressed: <br /> a. The structural calculations for the PT slab appear to include three cantilever slab segments <br /> along the balcony area. These segments do not appear on Sheet S2.08. The intended <br /> construction of the slab and balconies shall be clarified. <br /> b. The loads on the slab segments shall be clarified. The balconies will induce vertical and <br /> torsional loads along the slab edge. If the slabs are intended for modeling purposes only, <br /> documentation demonstrating how the segments effectively represent the canopy loads <br /> shall be submitted for review. The design loads shall include tributary loading from the <br /> canopy. <br /> c. Continuing with the previous comment, if the segments are for modeling only, the canopies <br /> are expected to have discrete connection points inducing concentrated moments along the <br /> slab edge. Documentation shall be submitted substantiating that the slab edge can support <br /> this loading. <br /> d. The balcony shall be designed for the seismic net upward force equal to 20% of the dead <br /> load per ASCE 7-10 Section 12.4.4. <br /> 28.The wood framing plans on Sheets S2.11 through S2.14 specify continuous FB-5 at multiple <br /> locations, such as Grid H.2. See IBC Section 107.2.1 and 1603.1The following comments shall <br /> be addressed: <br /> a. The framing is not drawn as continuous. See Sheet S2.15 which appears to show the <br /> framing as intended. The framing shall be revised. <br /> 0 3200 Cedar Street © 425.257.8810 0 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> C.:22.1e8of12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.