My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • • <br /> Plan Check Number PW1907-055 <br /> 2721 Wetmore Avenue <br /> Response to comments from First Building Review,August 26, 2019 <br /> I <br /> Items 36 a-g <br /> See Section A, Part A3 of the Supplemental Structural Calculations <br /> Item 36.h, i,j <br /> Does not apply with ELF procedure. <br /> Item 37 <br /> See Section A, Part A4 of the Supplemental Structural Calculations <br /> Item 38 <br /> See Section A, Part A3 of the Supplemental Structural Calculations <br /> f, <br /> Item 39 <br /> See Section C, Part C1 of the Supplemental Structural Calculations <br /> Item 40 <br /> See Section B Part B4- Level L2 Post Tensioned Slab Design (Updated) of the Supplemental <br /> Structural Calculations for updated hold-down forces used in design. The design favors steel yield in <br /> the anchor before concrete failure. Seismic loading and load combinations per ASCE 7-10 section <br /> 12.14.3.2 with exception noted have been included. Reference updated PT slab calculations. <br /> Item 41 <br /> See Section C, Part C1 of the Supplemental Structural Calculations. The in-plane shear strength of <br /> anchor bolts attaching wood sill plates to concrete shall be controlled by wood failure and shall be <br /> determined in accordance with the NDS table 11 E, per exception 1 on page450 of the IBC2015 code. <br /> Structural/Miscellaneous <br /> Item 42 <br /> In our opinion, accommodation of the elevator design loads and supports are best treated as a deferred <br /> submittal with project specific data once procured. We have included details in consideration of the <br /> comment so they are captured in the contractor's scope of work. <br /> age 15/5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.