Laserfiche WebLink
• 1, <br /> • • <br /> • <br /> Plan Check Number B1906-031 <br /> 2721 Wetmore Avenue <br /> Response to wood frame comments from Second Building Review,October 18, 2019 <br /> frame shrinkage for attachment of elevator rails is per elevator manufacturer.We note that this elevator <br /> is commonly used in wood frame and concrete podium structures without issue. <br /> Additional Comments <br /> Items 43 and 44 <br /> These two added comments repeat comments of Item 39c. Please see response to Item 39c. This <br /> issue has been asked and answered. Confirming again that we have met the requirements of all code <br /> requirements including consideration of direct shears, actual and accidental torsional effects of the west <br /> side open sided diaphragm and SDPWS Section 4.2.5.1 and 4.2.7.1. <br /> Item 45 <br /> Additional holdowns at each end of each wall segment have been added as suggested. Ref. Sheet <br /> S2.10A. <br /> PLEASE CALL WITH QUESTIONS. <br /> AEM/CTE <br /> Page 4 (� <br />