My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
>
Address Records
>
COLBY AVE
>
2722
>
COMMUNITY HEALTH CENTER
>
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:12:18 AM
Creation date
7/27/2023 10:02:47 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1--MWinistered by ©2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />C405.2.5, <br />Item 5 <br />C405.4.1 <br />C405.4.2 <br />'.41 <br />Indicate on plans that non -visual lighting are <br />controlled independently from both general <br />area lighting and other lighting applications <br />within the same space <br />Indicate nnethod of manual lighting control <br />and applicable automatic lighting control <br />Means of egress Identify on plans egress fixtures that function <br />lighting as both normal and emergency rneans of <br />egress illumination <br />Provide calculation of lighting power density I <br />of total egress lighting <br />If total egress lighting power density is greater <br />than 0.02 W/sq. ft., indicate on plans em-ess <br />fixtures requiring automatic shut-off during <br />unoccupied periods <br />Indicate method of automatic shut-off control <br />Lighting control of <br />Indicate that exempt interior lighting <br />exempt interior <br />equipment and lighting located within spaces <br />lighting i <br />that are eligible for a lighting power <br />i <br />exemption are controlled independently from <br />jnon-exempt <br />and general area lighting <br />Exterior lighting <br />For decorative exterior lighting, indicate on <br />controls <br />plans automatic daylight shut-off controls. or <br />exception taken. <br />For exterior lighting that is not decorative. <br />indicate on plans automatic daylight or time - <br />switch shut-off controls and setback controls, <br />or indicate exception taken <br />I <br />i <br />I <br />C405.5.2 Lighting control of <br />exempt exterior <br />ighting <br />i <br />For lighting requiring setback controls. <br />include control sequence that reduces lighting <br />power by at least 30% between I tam -barn, or <br />from 1 hour after closing to 1 hour before <br />opening. or based upon motion sensor <br />For building facade and landscape lighting, <br />indicate control sequence for shut-off control <br />is based on dawn -to -dusk and business <br />,pening/closing schedule: indicate whether <br />automatic or time switch controls will be <br />provided for this function <br />Indicate that exempt exterior lighting and <br />lighting located within exterior areas/surfaces <br />that eligible for a lighting power exemption <br />are controlled independently from non- <br />exempt exterior lighting <br />—T _ <br />C405.5.4 I Exterior gas -fired I indicate ignition system is a method other <br />lighting appliances then continuously burning pilot light <br />NA C405.2.7 Area controls - Indicate locadon(s) of master control the contractor will <br />Master control switch(es) intended to control multiple provide this if <br />switches and circuit independent switches; circuit breaker may not required <br />j power limit be used as a master control switch <br />Page 4110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.