Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all RI --lffninistered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA Verify that no 20 amp circuit controlled by a <br />single switch or automatic control is loaded <br />beyond 80% <br />ADDITIONAL EFFICIENCY CREDIT - ENHANCED INTERIOR LIGHTING CONTROLS <br />--- <br />C406.4 Enhanced digital To comply with additional efficiency credit, <br />lighting controls indicate on plans that interior lighting fixtures <br />are configured with all of the following <br />i control functions, as applicable: 1) Each <br />jI fixture is individually addressed, or exception <br />taken: 21 Fixtures are configured for <br />continuous dimming; 3) No more than eight <br />fixtures are controlled by a single daylight <br />sensor; 4) In enclosed and open office areas, <br />illumination levels of overhead general area <br />lighting is configured to be individually <br />adjusted by occupants <br />INTERIOR LIGHTING POWER & EFFICACY <br />C405.4.1 <br />C405.4.2 <br />C405.1 <br />C405..1. f <br />Include calculations that demonstrate the total <br />lighting power of all interior lighting fixtures <br />configured with enhanced lighting controls is <br />no Less than 901I: of the total interior ligliting <br />power for the area the enhanced fighting <br />controls credit is being applied to <br />Total connected <br />Include all luminaires in interior lighting <br />interior lighting <br />fixture schedule-, indicate fixture types, lamps, <br />power <br />ballasts, and manufacturer's watts per fixture <br />ffor the installed lamp <br />Identify spaces eligible for lighting power <br />exemption on plans and in WSEC interior <br />lighting compliance reports: indicate the <br />exception applied <br />I Identify lighting equipment eligible for <br />lighting power exemption in fixture schedule <br />and in WSEC interior lighting compliance <br />reports-. indicate the exception applied <br />Lighting in dwelling <br />I For all installed luminaires, include lamp type <br />units (multifamily) <br />and number of lamps in lighting fixture <br />schedule: for lamps that are not LED, T-8 or <br />small diameter fluorescent, indicate efficacy <br />of other lamp types is 65 lumens per watt or <br />greater <br />For all installed luminaires, indicate in <br />lighting fixture schedule whether complying <br />via lighting power density or by qualifying <br />lamp type; if by lamp type, include number of <br />lamps <br />For all installed luminaires, indicate in <br />lighting fixture schedule whether complying <br />via lighting power density or by qualifying <br />lamp type; if by lamp type, include number of <br />lamps <br />INTERIOR LIGHTING POWER CALCULATION - INDICATE COMPLIANCE PATH TAKEN <br />the contractor will <br />provide this if <br />required <br />Page 5110 <br />