Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 --ministered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />i <br />LIGHTING ALTERATIONS <br />F — -- <br />C503.6.1 <br />Interior and parking <br />garage lighting <br />fixture alterations <br />InteriorlightimY <br />wiring and circuiting <br />alternations <br />- -- _-- -- <br />Demonstrate that proposed wattage per non 1 <br />tradable surface type does not exceed <br />maximum allowed wattage per non -tradable <br />surface type (including base site allowance <br />remaining after tradable allowance <br />calculation): identify locations of non -tradable <br />surfaces on plans; provide WSEC exterior <br />lighting compliance reports <br />Where >_ 50% of existing luminaires in an <br />i <br />interior space or parking garage are replaced; <br />indicate compliance path (building area or <br />space -by -space method): include all new and <br />existing -to -remain luminaires in WSEC <br />interior lighting compliance reports: indicate <br />proposed lighting wattage does not exceed <br />maximum allowed per compliance path i <br />i Where < _50% of existing luminaires in an � <br />interior space or parking garage are replaced; I j <br />indicate total existing lighting wattage in each <br />space prior to alteration; include all new and j <br />existing -to remain luminaires in WSEC <br />interior lighting compliance reports; indicate <br />proposed total lighting wattage in alteration <br />area does not exceed total existing lighting <br />( wattage prior to alteration <br />Where > 50% of existing exterior lighting <br />wattage is replaced; include all new and <br />existing -to -remain luminaires in WSEC <br />exterior lighting compliance reports; indicate <br />I proposed total exterior lighting wattage does <br />inot exceed maximum allowed <br />Where < 50% of existing exterior lighting <br />wattage is replaced; indicate total existing <br />lighting wattage prior to alteration; include all <br />new and existing -to -remain luminaires in <br />WSEC interior exterior compliance reports; <br />indicate proposed total exterior lighting <br />wattage does nor exceed total existing wattage <br />prior to alteration <br />Where new wiring is installed to serve new <br />interior luminaires and ;or luminaires are <br />relocated to a new circuit: indicate manual <br />and automatic lighting controls are provided <br />(as applicable) - manual (C405.23), <br />occupancy sensor (C405.2.I ): light reduction <br />(C405.2.3); daylight responsive (C405.2.4): <br />specific application (C405.2.5) <br />Where new wiring is installed to serve new <br />exterior luminaires and /or luminaires are <br />relocated to a new circuit indicate automatic <br />lighting controls are provided (C405.2.6) <br />Page 7110 <br />