Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 --111iffministered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />C503.0-3 Lighting panel <br />alterations <br />C503.6.4 Newly -created rooms <br />NA C504.2 Lighting repairs <br />C505. <br />Change of interior <br />space use <br />RECEPTACLES <br />NA C405.10 Controlled <br />receptacles <br />NA <br />Where a new ulterior and/or exterior lighting <br />Ipanel is installer) or an existing panel is moved I <br />(all new raceway and conductor wiring), <br />indicate all applicable lighting controls j <br />requirements apply <br />Where interior space(s) is reconfigured <br />(permanently installed walls or ceiling -height <br />partitions) to create new enclosed spaces, <br />indicate all applicable lighting controls <br />requirements apply <br />Identify existing luminaires being upgraded <br />with bulb and / or ballast replacement; <br />indicate fixture alteration does not increase <br />existing fixture wattage <br />Identify spaces on plans where the building <br />area type or space use type is being changed <br />from one type to another per Tables <br />C405.4 20) or (2) <br />Indicate compliance method (building area or <br />space -by -space); include all new and existing - <br />to -remain luminaires in WSEC interior <br />lighting compliance reports:. indicate proposed <br />lighting wattage does not exceed maximum <br />allowed per compliance path <br />the contractor will <br />provide this if <br />required <br />I <br />i <br />i <br />i <br />t <br />Identify all controlled and uncontrolled the contractor will <br />receptacles on electrical plans in each space in provide this if <br />which they are required; include receptacle required <br />configuration such as spacing between <br />controlled and uncontrolled, duplex devices, <br />etc <br />Provide schedule that lists the number of the contractor will <br />controlled and uncontrolled receptacles in provide this if <br />each space where controlled receptacles are required <br />required - classrooms, private offices, open <br />office areas, conference rooms, copy rooms, <br />break rooms and modular <br />partitions/workstations <br />Indicate on plans the method of automatic the contractor will <br />control for each controlled receptacle zone provide this if <br />(occupant sensor or programmable time -of- required <br />day control); indicate that each zone served by <br />a single controller does not exceed 5.000 sf <br />i <br />C4o5.2.5, <br />Switched receptacles <br />Indicate method of automatic off control of <br />Item 2 <br />I in sleeping units <br />all switched receptacles in sleeping units <br />(vacancy or key card control) <br />i C503.6.6 <br />Electrical receptacle <br />Where new receptacles are added or replaced <br />alerations <br />within an alteration project that is 5,000 sf or <br />larger, indicate receptacles are provided with <br />automatic controls per C405.10, or exception <br />taken <br />MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION <br />Page 8110 <br />