My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
>
Address Records
>
COLBY AVE
>
2722
>
COMMUNITY HEALTH CENTER
>
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:12:18 AM
Creation date
7/27/2023 10:02:47 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 --111iffministered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />C503.0-3 Lighting panel <br />alterations <br />C503.6.4 Newly -created rooms <br />NA C504.2 Lighting repairs <br />C505. <br />Change of interior <br />space use <br />RECEPTACLES <br />NA C405.10 Controlled <br />receptacles <br />NA <br />Where a new ulterior and/or exterior lighting <br />Ipanel is installer) or an existing panel is moved I <br />(all new raceway and conductor wiring), <br />indicate all applicable lighting controls j <br />requirements apply <br />Where interior space(s) is reconfigured <br />(permanently installed walls or ceiling -height <br />partitions) to create new enclosed spaces, <br />indicate all applicable lighting controls <br />requirements apply <br />Identify existing luminaires being upgraded <br />with bulb and / or ballast replacement; <br />indicate fixture alteration does not increase <br />existing fixture wattage <br />Identify spaces on plans where the building <br />area type or space use type is being changed <br />from one type to another per Tables <br />C405.4 20) or (2) <br />Indicate compliance method (building area or <br />space -by -space); include all new and existing - <br />to -remain luminaires in WSEC interior <br />lighting compliance reports:. indicate proposed <br />lighting wattage does not exceed maximum <br />allowed per compliance path <br />the contractor will <br />provide this if <br />required <br />I <br />i <br />i <br />i <br />t <br />Identify all controlled and uncontrolled the contractor will <br />receptacles on electrical plans in each space in provide this if <br />which they are required; include receptacle required <br />configuration such as spacing between <br />controlled and uncontrolled, duplex devices, <br />etc <br />Provide schedule that lists the number of the contractor will <br />controlled and uncontrolled receptacles in provide this if <br />each space where controlled receptacles are required <br />required - classrooms, private offices, open <br />office areas, conference rooms, copy rooms, <br />break rooms and modular <br />partitions/workstations <br />Indicate on plans the method of automatic the contractor will <br />control for each controlled receptacle zone provide this if <br />(occupant sensor or programmable time -of- required <br />day control); indicate that each zone served by <br />a single controller does not exceed 5.000 sf <br />i <br />C4o5.2.5, <br />Switched receptacles <br />Indicate method of automatic off control of <br />Item 2 <br />I in sleeping units <br />all switched receptacles in sleeping units <br />(vacancy or key card control) <br />i C503.6.6 <br />Electrical receptacle <br />Where new receptacles are added or replaced <br />alerations <br />within an alteration project that is 5,000 sf or <br />larger, indicate receptacles are provided with <br />automatic controls per C405.10, or exception <br />taken <br />MOTORS, TRANSFORMERS, ELECTRIC METERS, INTERIOR TRANSPORTATION <br />Page 8110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.