Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1--'"Mministered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />C` 1t15 6 Electrical <br />I Include electrical transformer schedule on <br />transformers <br />1 electrical platy; indicate transformer type, <br />-i.>.e, efficiency, or exception taken <br />1� <br />NA C405.11 Feeders and branch <br />Provide documentation that demonstrates <br />the contractor will <br />circuits <br />maximum voltage drop across feeders and <br />provide this if <br />branch circuits does not exceed 5% <br />required <br />C405.7 <br />Dwelling unit <br />Indicate on electrical plans that each dwelling <br />electrical energy <br />unit in Group R-2 has a separate electrical <br />j <br />consumption <br />energy meter <br />_ ---- ---ii------ - —... —....... <br />....___.--- <br />C405.8 Electric motor Include all motors, includin- fractional hp <br />efficiency motors, in electric motor schedule on <br />electrical plans; indicate motor tvpe, <br />horsepower, rpm, rated efficiency, or <br />exception applied <br />C405.9.1 Elevator cab; I For lutrunaires in each elevator cab, provide <br />calculations that demonstrate average efficacy <br />is not less than 35 lumens pet watt <br />For elevators that do not have an integral air <br />conditioning system, indicate rated watts per <br />cfm for elevator cab ventilation fans do not <br />exceed 0.33 watts per cfin <br />Indicate automatic controls that de -energize <br />I <br />lighting and ventilation fans when elevator is <br />stopped and unoccupied for a period of 15 <br />minutes or more <br />-10.5.9 2 Escalators and <br />moving walks <br />Indicate escalators comply with ASME <br />A17.1/CSA B44; automatic controls are <br />I configured to reduce operational speed to the <br />minimum permitted when not in use <br />C405 4.3 <br />i Regenerative drive <br />Indicate all one-way down or reversible <br />escalators are provided with a variable <br />frequency regenerative drive <br />DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (CX) <br />NA C408.4 <br />Scope of electrical <br />Indicate that all electrical systems <br />the contractor will <br />power and lighting <br />(receptacles, transformers, motors, vertical <br />provide this if <br />systems <br />and horizontal transportation) for which the <br />required <br />commissioning <br />WSEC requires control functions and / or <br />configuration to perform specific functions <br />are required to be commissioned <br />NA <br />Where total building lighting load is > 20 kW, <br />the contractor will <br />or where total lighting load of luminaires <br />provide this if <br />requiring daylight sensing and / or occupancy <br />required <br />control > 10 kW, indicate that all automatic <br />lighting control systems are required to be <br />commissioned; or provide building lighting <br />power calculation demonstrating eligibility for <br />exception <br />NA C405.13 <br />Commissioning <br />Indicate Cx requirements in plans and <br />the contractor will <br />C408.1.1 <br />requirements in <br />specifications for all applicable electrical and <br />provide this if <br />C408.1.2 <br />construction <br />lighting control systems per C408 <br />i required <br />C408.1.4.2 <br />documents <br />C 103.6.3 <br />Page 9110 <br />