My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
>
Address Records
>
COLBY AVE
>
2722
>
COMMUNITY HEALTH CENTER
>
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:12:18 AM
Creation date
7/27/2023 10:02:47 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1--'"Mministered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />C` 1t15 6 Electrical <br />I Include electrical transformer schedule on <br />transformers <br />1 electrical platy; indicate transformer type, <br />-i.>.e, efficiency, or exception taken <br />1� <br />NA C405.11 Feeders and branch <br />Provide documentation that demonstrates <br />the contractor will <br />circuits <br />maximum voltage drop across feeders and <br />provide this if <br />branch circuits does not exceed 5% <br />required <br />C405.7 <br />Dwelling unit <br />Indicate on electrical plans that each dwelling <br />electrical energy <br />unit in Group R-2 has a separate electrical <br />j <br />consumption <br />energy meter <br />_ ---- ---ii------ - —... —....... <br />....___.--- <br />C405.8 Electric motor Include all motors, includin- fractional hp <br />efficiency motors, in electric motor schedule on <br />electrical plans; indicate motor tvpe, <br />horsepower, rpm, rated efficiency, or <br />exception applied <br />C405.9.1 Elevator cab; I For lutrunaires in each elevator cab, provide <br />calculations that demonstrate average efficacy <br />is not less than 35 lumens pet watt <br />For elevators that do not have an integral air <br />conditioning system, indicate rated watts per <br />cfm for elevator cab ventilation fans do not <br />exceed 0.33 watts per cfin <br />Indicate automatic controls that de -energize <br />I <br />lighting and ventilation fans when elevator is <br />stopped and unoccupied for a period of 15 <br />minutes or more <br />-10.5.9 2 Escalators and <br />moving walks <br />Indicate escalators comply with ASME <br />A17.1/CSA B44; automatic controls are <br />I configured to reduce operational speed to the <br />minimum permitted when not in use <br />C405 4.3 <br />i Regenerative drive <br />Indicate all one-way down or reversible <br />escalators are provided with a variable <br />frequency regenerative drive <br />DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING (CX) <br />NA C408.4 <br />Scope of electrical <br />Indicate that all electrical systems <br />the contractor will <br />power and lighting <br />(receptacles, transformers, motors, vertical <br />provide this if <br />systems <br />and horizontal transportation) for which the <br />required <br />commissioning <br />WSEC requires control functions and / or <br />configuration to perform specific functions <br />are required to be commissioned <br />NA <br />Where total building lighting load is > 20 kW, <br />the contractor will <br />or where total lighting load of luminaires <br />provide this if <br />requiring daylight sensing and / or occupancy <br />required <br />control > 10 kW, indicate that all automatic <br />lighting control systems are required to be <br />commissioned; or provide building lighting <br />power calculation demonstrating eligibility for <br />exception <br />NA C405.13 <br />Commissioning <br />Indicate Cx requirements in plans and <br />the contractor will <br />C408.1.1 <br />requirements in <br />specifications for all applicable electrical and <br />provide this if <br />C408.1.2 <br />construction <br />lighting control systems per C408 <br />i required <br />C408.1.4.2 <br />documents <br />C 103.6.3 <br />Page 9110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.