Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 --1411fministered by ©2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupportgwaenergycodes.com <br />Project: <br />Compass Health Care - Everett - 2018 WSEC <br />2722 Colby Avenue <br />3rd/4th floors <br />Everett, WA 98201 <br />Date: 2022-08-11 <br />Applies <br />Location in <br />Code Section <br />j Component <br />Compliance Information Required in Permit <br />Building Department <br />Documentation <br />Documents <br />Notes <br />LIGHTING SCOPE <br />1 <br />C t n ; I <br />-- - -- <br />Construction <br />__Fora shell & cote or tenant space (first build_ <br />documents - General <br />out) project, indicate if there is no lighting <br />scope included in the project. <br />YES <br />C 103.1 ! Construction <br />For an alteration project, indicate if there is <br />no new lighting - see <br />documents - General no lighting scope included in the project. <br />A 1.2 for RCP and the <br />minor relocations of <br />ex. fixtures due to <br />wall changes <br />LIGHTING CONTROLS <br />YES C405.2 <br />Lighting controls, <br />For all lighting fixtures, indicate lighting <br />I new switching is <br />general <br />control method on plans for spaces and <br />shown on the A1.2 <br />I <br />lighting zone(s) served, or exception taken <br />plans where indicated <br />C405.2, <br />I Luntinaire level <br />Indicate on plans all fixtures provided with <br />! <br />! <br />Option 2 <br />lighting controls <br />LLLC in lieu of C405.2 lighting controls; <br />I <br />(LLLC) <br />provide description of control capabilities and <br />performance parameters <br />'4o5.2.5, <br />1 Lighting in dwelling <br />I Indicate method of automatic control of all <br />Item 3 <br />units (dormitory, <br />installed luminaires in dwelling units in <br />C405.2.1.1 <br />hotel and all other <br />buildings other than multifamily (occupancy <br />C405 2.3.1 <br />than multifamily) <br />I or light reduction controls) <br />C405.2.5. <br />Lighting in sleeping <br />Indicate method of automatic off control of <br />Item 2 <br />units <br />all installed luminaires in sleeping units <br />j <br />(vacancy or kev card control): also refer to <br />Receptacles <br />C405.2.3 <br />! Manual controls <br />I <br />htdicate on plans the method of manual <br />C405.2.3.1 <br />lighting control, location of manual control <br />1 <br />I 1405.2.5 <br />I device and the area or specific application it <br />� <br />I <br />I <br />serves <br />indicate <br />C405.2.3.1 <br />( <br />Manual interior light <br />1 on plans which method of manual <br />C405.2, E I <br />reduction controls <br />501t� lighting load reduction is provided, or <br />C405.2.4 <br />! <br />; indicate applicable exception <br />C405.2.1 <br />i <br />— <br />Method of automatic I <br />Indicate on plans the method of automatic <br />j <br />C405.2.2.1 <br />shut -Off control <br />shut-off control during unoccupied periods <br />C405.2.1, <br />(occupancy sensor, time switch or digital <br />y <br />I <br />Exception 3 <br />j <br />timer switch) for all lighting zones <br />1 <br />C405.2.1 <br />Occupant sensor i <br />Indicate on plans all luminaires that are <br />controls <br />controlled by occupant sensor controls: <br />f <br />indicate controls are configured to turn <br />luminaires 100°/c off when the space is j <br />I <br />' <br />' <br />i <br />unoccupied <br />I <br />! <br />I <br />� <br />1 <br />3112 <br />Page 1/10 <br />