My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
>
Address Records
>
COLBY AVE
>
2722
>
COMMUNITY HEALTH CENTER
>
2722 COLBY AVE COMMUNITY HEALTH CENTER 2023-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 9:12:18 AM
Creation date
7/27/2023 10:02:47 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 1411111111ministered by ©2022 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial <br />Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />Ij C405.2.1 j Occupant sensor <br />I indicate if occupant sensor controls are <br />C405.2.1.1 controls <br />configured to be manual on or automatic on to i <br />not more than 50% power; indicate spaces <br />eligible for exception that : li .. automatic on <br />to 10011c, power <br />C405.2.1.2 Occupant sensor <br />Indicate each aisleway and corridor within a <br />controls - warehouses <br />warehouse space are designated as separate <br />spaces <br />zones that are independently controlled <br />NO <br />Indicate occupant sensors are configured to no warehouse spaces <br />automatically reduce lighting power by 50% <br />when the zone is unoccupied and 100% off <br />after the zone is unoccupied for over 20 <br />minutes; indicate controls are configured to <br />automatically restore lighting to full power <br />when the zone or space is occupied <br />NO C405.2.1.3 Occupant sensor <br />For open plan office areas larger than 300 sf, no open office areas <br />controls - open plan <br />indicate general lighting is provided with like this <br />office areas <br />vacancy controls that reduce lighting power by <br />not less than 80% and are configured to turn <br />luminaires 100% off when the space is <br />unoccupied; indicate that no individual control <br />zone area exceeds 600 sf <br />C405.2.1.4 <br />� Occupant sensor <br />Indicate parking garage general lighting is <br />j controls - parking <br />provided with vacancy controls that reduce <br />garages <br />lighting power by not less than 301,'r and are <br />configured to turn luminaires 100%: off when <br />no vehicles or pedestrians are present, unless <br />eligible for an exception; indicate that no <br />individual control zone area exceeds 3.600 sf <br />NA C405.2.1.5 <br />Occupant sensor <br />controls - enclosed <br />Indicate stairway lighting is provided with <br />vacancy controls that reduce lighting power by <br />all stair lighting is <br />existing to remain <br />fire -rated stairwells <br />not less than 50% when the stairway in <br />unoccupied <br />NA C405.2.2.1 <br />Automatic time <br />Indicate spaces on plans where time switch <br />all stair lighting is <br />switch controls <br />controls turn luminaires 100% off during <br />existing to remain <br />unoccupied hours <br />NA <br />Indicate spaces on plans where time switch <br />the electrical <br />controls are configured to turn on lighting to <br />contractor will <br />full power versus 50% power <br />provide the info for <br />this as requried <br />Indicate locations of override switches on <br />plans and the lighting zones served; indicate <br />that the area(s) served by each override switch <br />does not exceeds 5,000 sf <br />j C405.2.1, <br />--- <br />Digital timer switch <br />� Indicate digital timer switch control includes: <br />Exception 3 <br />manual on/off, time delay, audible and visual <br />indication of impending time-out <br />1 C405.2.4? <br />Daylight zones - <br />Indicate primary and secondary sidelit <br />C405.2.4.3 <br />Sidelit and toplit <br />I daylight zone floor areas on plans <br />Indicate toplit daylight zone floor areas on <br />i <br />plans <br />I <br />Page 2110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.