Laserfiche WebLink
. . , . . <br /> for experimental testing, may be accepted by the _: ire chief as <br /> prima facie evidence that any gravity oil burner complying <br /> with such regulations is safe for use within the A:ity of <br /> j: verett and the ,dire tihief may at his discretion permit the <br /> • <br /> installation and use of any such gravity oil burner, subject <br /> to the special provisions herein provided. <br /> (d) No gravity oil burner having an oil <br /> supply tank of a capacity exceeding _welve (12) gallons, <br /> shall be installed or used in any portion of a building used <br /> for the purpose of a hotel, apartment house or assembly hall, <br /> or a rooming house, boarding house, school, theater, church, <br /> department store, or a place of refuge or detention, or in any <br /> portion of a waterfront building extending over the waters of <br /> , verett .::.arbor or _ fiver. <br /> ( e) No gravity oil tank shall have an oil <br /> capacity in excess of two hundred ( 200) gallons when installed <br /> as an intregal part of a gravity supply tank system. <br /> ( f) atorage tanks shall be equipped ' ith an <br /> open vent extending from and above top of tank and provide <br /> with a return elbow properly screened. 'tent openings and <br /> vent pipes shall be of ample size to prevent abnormal <br /> pressure in the tank during filling, but shall not be smaller <br /> 'Clan one inch pipe size, and proportionately larger for <br /> correspondingly larger supply tanks. dent pipes shall be <br /> connected to the top of the tank and shall not extend through <br /> the top of the tank for a distance of more than one inch. <br /> (g) No oil burner connected to a gravity oil <br /> tank having a capacity in excess of ..welve (12) gallons shall <br /> be located above the lowest story of the building in which <br /> installed, or be less than ten (10) feet from any stove, <br /> furnace, boiler or other heating or heat radiating device . <br /> : hen the capacity of the gravity oil tank does not exceed <br /> Twelve ( 12) gallons, such tank may be located not less <br /> than "_hree (3) feet from such heating device ; provided, that <br /> gravity oil tanks of a capacity not in excess of 'ywelve ( 12) <br /> gallons mounted on the back of an oil circulating heater or <br /> range as provided by the manufacturer as an integral part of <br /> such heater or range, shall be permitted subject to the <br /> approval of the ire vhief. _ o gravity oil tank shall be <br /> located more than thirty Six (3d) inches above the oil burner <br /> to which it is connected. <br /> (h) ,.;ravity oil tanks shall be securely <br /> fastened in place on a strongly constructed sty:;nd adequately <br /> secured against overturning. ouch tanks installed inside <br /> buildings shall be mounted on a stand constructed of <br /> in Combustible material. <br /> ( i) gravity oil tanks of a capacity exceeding <br /> Three ( 3) gallons shall be constructed of galvanize_, stell <br /> -4- <br />