Laserfiche WebLink
40 <br /> AUGUST 13,2021 <br /> City of Everett <br /> Permitting Services <br /> 3200 Cedar Street,2"d Floor <br /> Everett,WA 98201 (�` <br /> RE: Plan Check Number: B2105-014 I( F1 <br /> Proposed Domino's 7134 Tenant Improvement ARCHITECTURE <br /> 1801 N Broadway Ave. STUDIO <br /> Everett,WA 98201 <br /> Gnich Architecture Studio has professionally taken over this project.Jason D.Gnich is the <br /> Registered Architect;AR 8911.A complete new set of construction documents are provided: <br /> RESPONSE TO ARCHITECTURAL COMMENTS: <br /> General: <br /> 1. The project lists the 2015 editions of the building codes.The 2018 editions should be listed.See <br /> EMC Section 16.005.030 and IBC Section 107.2.1. <br /> SHEET G1.0-CODE SUMMARY-PROPER CODE EDITIONS LISTED ON COVER SHEET. <br /> 2. The"Building Construction Data"section on Sheet G.1 should be revised to state the <br /> Construction Type as"V-B". See IBC Section 602.1 and Table 602. <br /> SHEET G1.0-BUILDING DATA-CONSTRUCTION TYPE V-B LISTED ON COVER SHEET. <br /> 3. Work on existing buildings should comply with the IEBC.The IEBC provides three alternative <br /> methods for performing work:the Prescriptive Compliance Method(Section 301.3.1),the Work <br /> Area Method(301.3.2),and the Performance Compliance Method(301.3.3).The method <br /> selected for the project should be specified in the General Notes on Sheet G.1.A statement <br /> should be provided clarifying the types of work that are included in the project(e.g., repairs, <br /> additions,change of occupancy,etc.)and referencing the appropriate IEBC sections. The <br /> comments provided herein presume the project will comply with the Work Area Method of <br /> Chapter 6. Based on a review of the construction drawings,the proposed project appears to <br /> include the following work:Level 3 Alternations(Chapter 9). Additional and alternative types of <br /> work required for the project should be identified by the designer-of-record. See IBC Section <br /> 101.4.7,and IEBC Sections 301.3 and 604. <br /> SHEET G1.0-TENANT MPROVEMENT IS A LEVEL 3 ALTERATION.SCOPE OF WORK AND ALL REQUIRED <br /> PROJECT DATA PROVIDED ON COVER SHEET. <br /> 4. The plans should include a list of deferred submittals.See IBC Section 107.3.4.1. Identified <br /> deferred submittals include but are not limited to: <br /> a. Mechanical,including walk-in cooler(may be submitted separately). <br /> b. Electrical. <br /> c. Plumbing. <br /> d. Type I and II Hoods(requires a mechanical permit separate from base mechanical permit). <br /> SHEET G1.0-DEFERRED SUBMITTAL ITEMS LISTED UNDER"SUBMITTALS BY OTHERS". <br /> ELECTRICAL,MECHANICAL AND PLUMBING DRAWINGS ARE PROVIDED. <br /> STRUCTURAL PLANS TO BE PROVIDED. <br /> 1001 SE SANDY BLVD,SUITE 100,PORTLAND,OR 97214 V. 503.552.9079 F 503 241 7055 WWW.GNICHARCH.COM INQUIRY(a�GNICHARCH.COM <br /> \ 1, 3 <br />