drawings based on the best available information, and discrepancies can be resolved during <br />construction; selective demolition is recommended prior to construction to verify significant <br />conditions that may impact the project. If preferred, use two designations on the drawings to <br />distinguish between existing construction being permitted and new construction. Note that all <br />existing unpermitted construction is required to comply with the current codes; opening of wall <br />and ceiling finishes may be required by the inspectors to verify the construction. <br />The building code requires all projects involving modifications to the building to install smoke <br />and CO detectors (IRC Sections R314.2.2 and R315.2.2; see the WAC amendments for both of <br />these citations). Work involving only roofing, door and window replacement, and utility -only <br />projects (i.e., electrical, plumbing, mechanical) are exempt from these requirements. Properly - <br />located detectors are exempt from the requirement to interconnect the smoke alarms. <br />Buildings are also required to provide at least one handrail at all stairways, and guards along all <br />walking surfaces higher than 30" above the adjacent lower surface or ground (2015 IPMC <br />Section 307.1); these are required for every building regardless of whether a project is <br />performed. <br />