My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1710 W MARINE VIEW DR SOUND 2 SUMMIT 2023-10-23
>
Address Records
>
W MARINE VIEW DR
>
1710
>
SOUND 2 SUMMIT
>
1710 W MARINE VIEW DR SOUND 2 SUMMIT 2023-10-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 8:41:32 AM
Creation date
9/12/2023 7:21:52 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1710
Tenant Name
SOUND 2 SUMMIT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ntertok <br />Total Quality. Assured. <br />TEST REPORT FOR WESTWOOD INVESTORS, LLC <br />Project No.: N8834.01-901-43 <br />Date: 06/02/23 <br />SFrT1nn1 r, <br />EQUIPMENT SETUP <br />22155 68th Avenue South <br />Kent, Washington 98032 <br />Computer Setup <br />A laptop computer utilizing TECLOG4 software was set up to monitor and control all test <br />equipment. Fan flows, building enclosure pressures, and key interior building pressures were <br />monitored throughout the test. <br />Fan Setup <br />TEC (The Energy Conservatory) Model 3 fans were set up in the exterior doors (Reference Section <br />11, Photographs - Photo 5 and Section 12 - Location Plans). The number of fans set up was based <br />on the allowable leakage rate to ensure the available cfm achieved the pass/fail criteria of <br />the enclosure. TEC DG700/1000 manometers were set up to collect fan flows and control fan <br />speeds with the computer. <br />Induced Pressure Difference Variation <br />Interior pressure taps were run to building locations susceptible to significant pressure variations. <br />The difference between the highest and lowest pressure difference within the test enclosure was <br />less than 10% of the induced enclosure pressure. Pressure difference measurements were <br />monitored throughout the test to confirm uniform pressurization (reference "Interior Envelope <br />Pressure Reference" Locations, Section 12 - Location Plans). <br />GAUGES: <br />SERIAL NO.: <br />DG1000 <br />11732 <br />FANS: <br />SERIAL NO.: <br />TEC Model 3 <br />32147 <br />Page 4 of 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.