My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3409 FEDERAL AVE 2023-12-07
>
Address Records
>
FEDERAL AVE
>
3409
>
3409 FEDERAL AVE 2023-12-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 11:48:44 AM
Creation date
9/22/2023 1:19:59 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3409
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
components should be similarly delineated from existing component that are not being altered. See <br /> IRC Section R106.1.1. <br /> Architectural: <br /> 5. The project may require modifications to the stairs notably for egress from the basement. Details for <br /> the construction should be included. The stringers should comply with the joist span tables <br /> considering the net depth after notching for steps. The stair rise and run, and width, should be <br /> specified. A section showing the headroom clearances should be provided. Landings are required at <br /> the top and bottom. Include details for the guards. Handrails should be provided. Structural <br /> modifications may be required. See IRC Section R311.7. <br /> 6. Handrails should be specified for all stairways. See IRC Section R311.7.8. <br /> 7. The bedrooms should have emergency egress openings. The minimum opening dimensions and area, <br /> and maximum bottom sill opening height of the floor, should be specified. Structural modifications <br /> may be required. See IRC Section R310. <br /> 8. Smoke and CO alarms should be provided per IRC Sections R314 and R315. The locations of all alarms <br /> should be shown on the plans. The alarms should be hardwired, interconnected, and provided with <br /> back-up battery power as required. <br /> 9. Insulation should be specified for all exterior walls, floors, slab-on-grade, and ceiling/roof cavities per <br /> WSEC Table 402.1.1. <br /> 10. The required thermal ratings for each type of vertical fenestration should be specified. See WSEC <br /> Table R402.1.1. <br /> 11. The project involves increasing the conditioned space at the upper floor. Energy credits are required <br /> per WSEC Section R406. The required number of credits should be normalized per Table R406.2. A <br /> schedule of the selected credits should be included in the drawings. The performance requirements <br /> for the selected credits should be specified. <br /> 12. The project requires a whole house ventilation system per IRC Section R303.4. Show the location on <br /> the plans; the fan should not be located inside a closed room. Specify the performance requirements <br /> per Section M1505.4. <br /> 13. The bathrooms and kitchen should specify exhaust fans including the minimum required performance <br /> rates per IRC Table M1505.4.4(1). <br /> 14. The house is required to have a heating system per IRC Section R303.9. The type and location of the <br /> system should be specified. If the system is new, it should be indicated as such in the drawings. Gas <br /> appliances are prohibited in the locations specified in Section G2406. <br /> 15. The house is required to have a water heating system per IRC Section R306.4. The type and location of <br /> the system should be specified. If the system is new, it should be indicated as such in the <br /> drawings. Seismic restraints should be provided per Section M1307.2. Gas appliances are prohibited in <br /> the locations specified in Section G2406. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.