s <br /> 4. A handrail should be specified. Due to the conditions on the outer side of the lower run, the handrail <br /> should be placed along the inner side of the stairs. SHT A-1.0 GUARDRAIL PERSP. 1 &2, LOWER FLOOR w/ <br /> PROPOSED WORK. <br /> 5. The winders should be revised to provide the minimum interior tread depth of 6 inches. Verify the <br /> revised winder steps are uniform as required. SHT A-5.0 FLOOR FRAMING OVER KITCHEN—INDICATES <br /> MIN. 6" RUN AND UNIFORM WINDER STEPS. <br /> 6. Attic access should be provided for the spaces along each side of the upper level. SHT A-1.0 UPPER FLOOR <br /> PLAN <br /> 7. Roof ventilation should be provided for the attic spaces along each side of the upper level. Provided that <br /> the roof above is constructed as a non-vented roof,ventilation is not required overhead; details <br /> confirming construction complying with the non-vented roof requirements of the IRC should be included. <br /> SHT A-3.0 SEC. 7 THRU KITCHEN. <br /> 8. The upper level (e.g., walls, roof, etc.), and the exposed ceiling spaces over the first story(i.e., attic spaces <br /> to each side of the upper level) are required to comply with the insulation requirements of the WSEC for <br /> new construction. This includes changing out any existing windows to new windows. Note that the spray <br /> foam should be clarified as "closed cell" as it appears this type will be necessary for the project. SHT A-3.0 <br /> SEC. 7 THRU KITCHEN. <br /> 9. The project requires energy credits per the WSEC. A schedule should be included in the drawings. The <br /> performance requirements for the selected credits should be specified. ENERGY CREDIT FORMS <br /> ATTACHED TO THIS RESPONSE. <br /> 10. The smoke/CO alarm note should also state that the system is connected to the building's primary <br /> electrical system (i.e., hardwired). SHT A-1.0 UPPER FLOOR PLAN—SIDE NOTE. <br /> Please let me know if you have questions. <br /> Dean Dariotis, AIA <br /> Alex Dariotis, CPM _ WOODWAY HOMES,INC. Dean Dariotis,AIA <br /> PHONE 425-773-4356 PHONE 425 772-3167 <br />
The URL can be used to link to this page
Your browser does not support the video tag.