Laserfiche WebLink
DETECTOR BASES TECHNICAL SPECIFICATIONS <br /> The KS-PS detector head attaches easily to these compatible <br /> bases. Detector bases have wiring terminals that are accessible Operating voltage 24 VDC(nominal) <br /> from the "room-side" after mounting the base to the electrical <br /> box.A trim ring is supplied with the 4-inch base to help hide sur- Current <br /> face imperfections. Normal Operating 150 pA <br /> • Model DS-SB Standard Base: Connects the detector to Alarm 220 pA <br /> the Signaling Line Circuit(SLC). <br /> • Model DS-RB Relay Base: Connects the detector to the SLC Protocol SmartOne <br /> Signaling Line Circuit(SLC)and provides optional Relay 0.5 to 3.50 %/ft. (2.95 to 11.48%/m) <br /> functionality to the KS-PS detector. UL/cUL smoke <br /> sensitivity range obscuration <br /> ORDERING INFORMATION (Open Area Use Only) <br /> KS-PS Intelligent Photoelectric Smoke Detector, NOTE: <br /> head only Smoke sensitivity is selected at the control unit or with the <br /> remote configuration software. Default values are 2.0%/ft <br /> (Alarm)and 1.5%/ft(Pre-Alarm). Refer to the Installation, <br /> Operation and Maintenance Manual or the Configuration <br /> Software User Guide for your system. <br /> North American UL 268 (7th edition), UL 268A, <br /> standards CAN/ULC-S529,FMApprovals3210 <br /> Compliances: <br /> DS-SB Detector Mounting Base,4 in. diameter, •This device complies with Part 15, Class A of the FCC Rules. <br /> with 6 in.trim ring,for 2-wire connection to Operation is subject to the following two conditions: (1)This <br /> SmartOne SLC device may not cause harmful interference,and(2)this device <br /> r must accept any interference received, including interference <br /> that may cause undesired operation. <br /> .�, ICES-003, Class A <br /> j44EN 55011, Class A <br /> 1 ice' <br /> �,•e ��, • AS/NZS CISPR 11, Class A <br /> Air velocity 0 to 4,000 ft./min (0 to 20.32 m/s) <br /> Compatible bases DS-SB (Standard), DS-RB(Relay) <br /> DS-RB Detector Mounting Base,4 in. diameter, <br /> with relay option and 6 in.trim ring,for 2- Wall mounting: <br /> wire connection to SmartOne SLC distance from ceiling 12 in. (305 mm) max. <br /> k Operating Environment <br /> Temperature 32 to 120°F (0 to 49°C) <br /> ® ? ` Relative humidity 0 to 93% non-condensing <br /> Storage temperature -4 to 140°F (-20 to 60°C) <br /> Environmental <br /> compensation Automatic <br /> SM200-12PKG Canned smoke for functional testing of Color White head and base <br /> smoke detectors, package of 12 <br /> Construction High impact engineering polymer <br /> SIGA-LED Optional Remote Alarm LED <br /> Mounting Plug-in <br /> SIGA-VA Detector Vacuum Attachment <br /> SIGA-RTA Detector Removal Tool Attachment <br /> Kidde 2 K-71-101 <br /> Fire Systems Effective:October 2020 <br />