Laserfiche WebLink
Drew Martin <br />From: Drew Martin <br />Sent: Monday, October 4, 2021 2:09 PM <br />To: jnevins1214@yahoo.com <br />Subject: City of Everett Permit Services: 2308 Taylor Drive (B2109-081) - First Building Intake <br />Review <br />Attachments: SnoCo Field Assessor Record_2308 Taylor Drive.pdf; 2018 IRC-Typical Code References_ <br />04-12-2021.docx; CoE_Residential Drawing Preparatio n_Edited 09-27-2021.pdf <br />Hello, Ms. Nevins. <br />Your application has been received and a permit set up. However, the submitted documents are not <br />sufficiently developed for us to perform a comprehensive review at this time. <br />Information is attached to provide guidance. Construction -level documents should be submitted for <br />review. Two complete sets of the revised drawings should be submitted to replace the previously submitted <br />drawing sets. Preliminary comments are provided below to assist in preparing the drawings, but these are not <br />intended to provide a comprehensive review. The resubmittal documents should include an itemized <br />response letter clarifying how the review comments below have been addressed. Depending on your <br />experience with the adopted codes and preparing documents, we recommend consulting with a design <br />professional to assist you. <br />Intake Review Comments: <br />General: <br />1. The project should specify the applicable building codes, including but not limited to the 2018 IRC, <br />2018 WSEC, and the 2018 IBC. See Section R106.1.1 and EMC Section 16.005.030. <br />The submitted documents include sketches for the proposed project. Construction -level drawings <br />prepared using established drafting standards are required to substantiate compliance with the <br />IRC. The drawings should include plans, building sections, details, material specifications, design loads, <br />architectural and structural notes, etc. as needed to clearly show the proposed work. The current <br />editions of the building codes applicable to the project should be specified. See IRC Section R106.1.1. <br />The submitted drawings appear to include prior unpermitted work, including but not limited to <br />creating new living space with a second kitchen, and modifying the existing living space (e.g., moving <br />bathroom and kitchen fixtures, modifying walls, etc.). The existing conditions shown in the drawings <br />are not consistent with the available City of Everett and Snohomish County records. A copy of the old <br />SnoCo Field Assessor record is attached; note that the SnoCo records only provide a record of the <br />building condition for the purpose of assessing taxes and do not substantiate a permitted <br />condition. The drawings are also not consistent with photography available on Google Earth and the <br />real-estate website Redfin.com. The drawings should be revised to show all previous unpermitted <br />work as new work; all new work is required to comply with the current code <br />requirements. Alternatively, the drawings should show the removal of unpermitted work and <br />