Mr. Jonathan Rempel <br /> Plan Check Number: B2006-005, First Building Review <br /> July 15, 2020 <br /> 7. The proposed project appears to include emergency escape window wells on the west side. <br /> See IRC Section R310. The following comments should be addressed: <br /> a. A section should be provided through the window wall and wells indicating the vertical <br /> dimensions. <br /> b. The windows should specify the minimum requirements per Section R310.2.1. <br /> 8. The proposed project is converting a SFR into two dwelling units with modified rooms on both <br /> levels. Each habitable room should comply with the minimum area and dimension requirements <br /> of IRC Section R304. Dimensions for all rooms should be specified. <br /> 9. The proposed project includes converting an unfinished basement into a new dwelling unit. <br /> The unit is required to have minimum ceiling heights complying with IRC Section 305.1. The <br /> clearances should be shown in the drawings. <br /> 10. The proposed project includes an apparent six-foot addition on the south side at the Main level. <br /> The following comments should be addressed: <br /> a. The size of the proposed addition should be dimensioned. See IRC Section R106.1.1. <br /> b. The south side faces the property frontage. The site plan on Sheet A-1 should be revised to <br /> specify the minimum required setback on this side. See IRC Section R106.2. <br /> 11. The proposed project converts the existing SFR into two dwelling units. The floor-ceiling <br /> assembly separating the units should have a minimum fire-resistance rating of 1 hour per IRC <br /> Section R302.3. Details for the construction of the assembly demonstrating the minimum <br /> required fire-resistance should be provided. In addition, penetrations of the assembly should <br /> comply with Sections R302.4.1 and R302.4.2. <br /> 12. The proposed project appears to include substantial modifications to the existing structural <br /> systems, including the walls, floor, roof, and foundations. Framing plans and details should be <br /> included clearly indicating the existing and new construction. Note that it is not clear if the <br /> proposed design will comply with the prescriptive requirements of the IRC. Structural <br /> calculations demonstrating compliance with the IBC should be submitted for review. See IRC <br /> Sections R301.1.2 and R301.1.3. <br /> 13. The proposed project appears to remove the existing braced wall line at south exterior wall. <br /> The new building configuration should comply with the requirements of IRC Section R602.10. <br /> Note that the distance between braced wall lines for the east-west direction appears to be 62 <br /> feet, which exceeds the limits of Table 602.10.1.3 for both wind and seismic design. A lateral <br /> design for the modified structure should be performed per IRC Section 301.1.3. <br /> 14. Continuing with the previous project, the addition on the south side appears to be foundation <br /> above or behind and existing concrete retaining wall. Calculations substantiating the design of <br /> the wall should be submitted for review. See IRC Section R301.1.3. <br /> 15. The minimum fastening requirements should be specified. See IRC Table R602.3(1). A <br /> schedule should be provided including but not limited to: <br /> a. Wall studs to top and bottom plates. <br /> b. Top plate splices. <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.