My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1033 TEMPLE DR 2023-10-31
>
Address Records
>
TEMPLE DR
>
1033
>
1033 TEMPLE DR 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 10:31:39 AM
Creation date
10/24/2023 11:01:16 AM
Metadata
Fields
Template:
Address Document
Street Name
TEMPLE DR
Street Number
1033
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Jonathan Rempel <br /> Plan Check Number: B2006-005, First Building Review <br /> July 15, 2020 <br /> c. Roof and floor framing. <br /> d. Beams and header to supporting framing (e.g., king and jack studs). <br /> e. Wall corners. <br /> f. Roof and floor sheathing. <br /> 16. The proposed project is required to have smoke and carbon monoxide detectors per IRC <br /> Sections R314.2.2 and R315.2.2. <br /> 17. The proposed project is required to comply with the residential provisions of the 2015 <br /> Washington State Energy Code for new construction. See WSEC Sections 502.1 and 503.1. <br /> Requirements include but are not limited to: <br /> a. Minimum wall thermal rating of R-21 per Table 402.1.1. <br /> b. Minimum roof thermal rating of R-38 per Table 402.1.1 Footnote (k). <br /> c. Below grade walls insulated per Table R402.1.1. <br /> d. Minimum foundation thermal rating of R-10 for two feet per Table 402.1.1. <br /> e. Windows and doors should have a maximum thermal rating of U=30 per Table 402.1.1. <br /> f. Each dwelling unit should complete with the energy efficiency requirements of Section 406. <br /> The selected energy credits per Table R406.2 should be specified in the drawings. Separate <br /> credits should be specified for each unit. <br /> 18. The proposed project should specify ventilation and exhaust for each unit per IRC Section R303. <br /> The units should include a whole house ventilation system. <br /> 19. The proposed project should specify exhaust for each unit per IRC Chapter 15. Exhaust fans <br /> should be provided in each bathroom, laundry room and over kitchen ranges. <br /> 20. The project should specify heating and cooling systems for each unit per IRC Chapter 14. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.