My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1033 TEMPLE DR 2023-10-31
>
Address Records
>
TEMPLE DR
>
1033
>
1033 TEMPLE DR 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 10:31:39 AM
Creation date
10/24/2023 11:01:16 AM
Metadata
Fields
Template:
Address Document
Street Name
TEMPLE DR
Street Number
1033
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From: Drew Martin <br /> Sent: Wednesday, November 25, 2020 12:34 PM <br /> To: Jonathan Rempel <br /> Cc: Willard Williams; Grace Pollard <br /> Subject: City of Everett Permit Services: 1033 Temple Drive (B2006-005)-Second <br /> Building Review <br /> Good afternoon,Jonathan. <br /> I have performed an initial review of the resubmitted plans for this project. Unfortunately, I am not <br /> able to complete the review at this time. The plans appear to only be partially developed and do not <br /> provide sufficient clarity or detail to indicate the proposed work. In addition,the house as shown <br /> does not appear to match the existing conditions. In lieu of a second review letter, I am providing a <br /> brief list of my observations to supplement the original review comments. These do not need to be <br /> addressed directly. The plans should be revised and an updated response to the original review <br /> comments should be provided. Note that the responses provided to the review comments were <br /> similarly not sufficient to clearly indicate how all comments were addressed; a response was not <br /> provided for multiple comments. <br /> Here is a brief list of my observations: <br /> A.The plans generally do not provide a clear and constructible set of drawings. <br /> B.The plans do not delineate between the existing and new construction. <br /> C.The plans are not aligned on Sheet A1.6 versus Sheet 5200. The relationship between the <br /> levels is not clear. <br /> D.The plans do not appear consistent with the existing condition. Notable differences include but <br /> are not limited to: <br /> 1.The sections on Sheet A1.5 shows the roof ridge on the wrong side of the house. See also <br /> Sheet A1.8 which appears to show the ridge on the correct side. <br /> 2.The sections on Sheet A1.5 show a retaining wall on the east side that does not appear to <br /> exist. <br /> 3.The plans indicate the lower level is daylit on the east side, but photography shows the <br /> structure as buried. See also Section 2/A1.8 which is not consistent with Sheet A1.5. <br /> 4. Photography shows that the existing house has an unfinished 8-foot tall foundation <br /> structure about 10 from the building and open to the street. This is not shown on the <br /> plans, and is not consistent with the new foundation shown on Sheets S200, which only <br /> extends about 6 feet from the existing south building face. <br /> 5.The isometric view on Sheet A1.5 shows two dormers that are note existing. <br /> 6. Photography shows a building extension on the south side at the main level. This is not <br /> indicated for demolition in the plans. <br /> E.The walls, roof, and floors in Section 2/A1.8 are filled solid black. The construction is not clear. <br /> The provided clearance for the Basement level is not clearly shown. <br /> F.The furring construction at the Basement level is not clearly shown in Sheets A1.6 and A1.8. <br /> G.The plans on Sheet A1.6 appear to show new concrete window wells. The information is not <br /> adequate for their construction. Details do not appear to be provided in the structural <br /> drawings. The center window appear to be wider than the well. <br /> H.The windows in the well do not appear to satisfy the egress dimensions requirements. <br /> I.The extend floor at the Ground Floor in Plan 1/A1.6 is not insulated. <br />
The URL can be used to link to this page
Your browser does not support the video tag.