My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2610 HILLSIDE LN 2023-10-26
>
Address Records
>
HILLSIDE LN
>
2610
>
2610 HILLSIDE LN 2023-10-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 2:44:01 PM
Creation date
10/25/2023 3:21:28 PM
Metadata
Fields
Template:
Address Document
Street Name
HILLSIDE LN
Street Number
2610
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Architectural • <br />1. The Stair Section 2/A4.3 appears to show that the stairway does not have the minimum 6'- <br />8" clearance required per Section R311.7.2. The minimum clearance should be specified. <br />The design may need to be revised if the minimum clearance is not provided. <br />Response: Section 2/A4.3 has been revised to show 7'-0" clearance. <br />2. The exiting Bedroom 2 in the Lower Floor Plan on Sheet A2.1 should be provided with an <br />egress window per Section R310.2. <br />Response: Egress window is shown on the revised sheet A2.1. <br />I The guard around the stairs per the Main Floor Plan on Sheet A2.2 appears to be intended <br />as a proprietary system. The new deck on the north side of the building also appears to <br />include a guard system per Elevation 2/A3.1; the deck guard is not shown in the plan. The <br />following comments should be addressed: <br />a. The guards and connections to the supporting framing are required to resist a 200 lb <br />load per Table R301.5. A note should be provided. <br />Response: A General note as indicated above has been added to the revised <br />Sheet A2.2. <br />b. The framing around the opening perimeter should be sufficient to facilitation the <br />connection of the guard and develop the 200 lb load. <br />Response: Same as above. <br />c. The exterior guard connections should be detailed to prevent water infiltration, <br />particularly where the deck encloses interior space below. <br />Response: A note has been added to Revised Section 1/A4.1 to indicate <br />guardrail connection to be flashed to prevent water infiltration to the deck <br />structure below. <br />4. The new exterior walls for the Lower Floor gym do not appear to include a raised foundation <br />wall, placing the wood -framed construction within 2 inches of the exterior grades. The wall <br />construction, including the siding, should be decay -resistant construction per Section R317. <br />Detail 7/S4.1 is notes as providing this clearance. However, the building sections on Sheet <br />A4.1 do not indicate this will be provided, notably where an exterior slab -on -grade occurs. <br />Response: Exterior walls to Exercise room have been revised to add a <br />concrete curb. See new detail 5/A4.1. <br />'Id 300.629.3441 1 Fax .360.629.6159 <br />P.O. Box 1270 ! 10031 SR 532, Suitr B 1 Stanwood, WA 98292 <br />DcsIgnsN\X'.ront <br />Page 2 of 3 <br />