My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3430 NORTON AVE 2024-02-20
>
Address Records
>
NORTON AVE
>
3430
>
3430 NORTON AVE 2024-02-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2024 7:51:25 AM
Creation date
12/21/2023 11:24:33 AM
Metadata
Fields
Template:
Address Document
Street Name
NORTON AVE
Street Number
3430
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�l� �� ' ram^ ! i <br /> Mr. Dave Marlow ;,,�r� <br /> Integrity Custom Builders LLC D ;Lc 1L=;w-E <br /> Plan Check Number: B2107-048, First Building Review <br /> August 12, 2021 OC1 1 4 2021 <br /> General CITY OF EVERETT <br /> Permit Services <br /> The architectural and structural general notes on Sheets 4 and S-i.u, respectively, reference the <br /> 2015 versions of the building codes. The proposed project should comply with the requirements of <br /> the 2018 editions of the IRC and IBC. The drawings should be revised as needed to comply with <br /> the current code requirements. See Section R106.1.1 and EMC Section 16.005.030. See sheet 4 <br /> A The project includes a site plan that does not clearly show the proposed location of the building on <br /> the lot. The plan should be revised. Fire separation distances (FSD) with the lot lines and the <br /> existing single-family residence (SFR) should be specified. An imaginary lot between the existing <br /> and new buildings should be shown. Note that the Planning department has also issued comments <br /> on this issue; see the Planning correction letter emailed on 08/05/2010 for additional information. <br /> See Section R106.2 and additional comments below. <br /> Architectural <br /> y The building appears to be located with FSD to the property lines of less than 2 feet. See Table <br /> 302.1(1). The following comments should be addressed: walls are at 5ft — See site plan <br /> a. The building is required to have fire-rated walls on the north and west sides. Details providing <br /> listed tested assemblies should be included in the construction drawings. The details should <br /> include the assembling listing number. <br /> b. Openings in the exterior walls are not permitted on the north and west sides. The windows <br /> should be removed. Note that the closet window shown in the Floor Plan on Sheet 1 is not <br /> shown in the Rear Elevation. Not Applicable <br /> c. Continuing with the previous comment, roof ventilation openings are similarly not permitted <br /> along the west eave. See additional comments below. Non Vented Roof <br /> d. Eaves (i.e., projections) are not permitted along the north and west sides. Note that if the FSD <br /> to the roof eave exceeds 2 feet but is less than 5 feet, fire-rated construction is required. <br /> e. Continuing with the previous comment, the eave and rake dimensions should be specified in the <br /> construction plans for all sides of the building. See sht 1 — right & rear elevations <br /> V The building is understood to be located within the minimum lot setbacks and may required <br /> relocation by the Planning department. Depending on the revised location, the building may be <br /> subject to additional fire-rated construction requirements along the south and east walls due to FSD <br /> with the existing SFR. An additional permit to modify this structure may be required to modify the <br /> existing SFR is adequate FSD are not maintained. See Table R302.1(1). <br /> The FSD distance does not permit installation of ventilation openings along the north and west <br /> sides, preventing adequate distribution of ventilation openings at the building perimeter. The roof <br /> system should be revised to be an unvented roof. See Section R806.5. <br /> 'invented root, see sheet 3 <br /> 3200 Cedar Street 425.257.8810 everetteps@everettwa.gov <br /> - Everett, WA 98201 - 425.257.8857 fax = everettwa.gov/permits <br /> P. 1ot-5 L..4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.