My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
920 MILLWRIGHT LOOP S BASE FILE Geotech Report 2023-12-29
>
Address Records
>
MILLWRIGHT LOOP S
>
920
>
BASE FILE
>
Geotech Report
>
920 MILLWRIGHT LOOP S BASE FILE Geotech Report 2023-12-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 3:28:33 PM
Creation date
12/29/2023 3:26:05 PM
Metadata
Fields
Template:
Address Document
Street Name
MILLWRIGHT LOOP S
Street Number
920
Tenant Name
BASE FILE
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
very loose to medium dense, fine to medium sand with variable silt content containing shell fragments and <br />significant wood debris at some locations. Interbedded soft silt layers were encountered within the fill. <br />Recent deposits were encountered below the fill and generally consist of very loose to medium dense, fine <br />sand with variable silt content, and very soft to medium stiff sandy/clayey sift. Interbedded soft clay layers <br />were encountered within the recent deposits. <br />Glacially consolidated soils were encountered below the recent deposits and generally consist of dense to <br />very dense send with variable silt and gravel contents and hard sandy silt, extended to the depths explored. <br />Glacially consolidated soils are considered as competent bearing soils. <br />The locations of the standard penetration lest (SPT) and cone penetration test (CPT) borings that were <br />reviewed and used in our analyses are shown in the Site Plan (Figure 2). The corresponding SPT and CPT <br />logs are presented in Appendix A, Previous Subsurface Investigations. <br />2.3. Groundwater Conditions <br />Based on the reviewed information, the design groundwater level was assumed at Elevation 0.00 feet on <br />the water side in front of the bulkhead and at Elevation t12.00 feet on the land side behind the bulkhead. <br />3.0 DESIGN CROSS SECTION <br />Cross Section A -A', the location of which is shown in Figure 2, was selected for use in our geotechnical <br />analyses. The soil delineation for Cross Section hA' is presented in Figure 3. Due to the lack of subsurface <br />exploration Information on the water side, according to the nearby projects along the bulkhead segments; <br />A, B, and C, we assumed marine area fill being backfilled at the toe of the bulkhead to achieve the 2.5H:SV <br />slope from Elevation 0.00 feet to Elevation -9.00 feet. The soil profile behind the bulkhead was horizontally <br />extended to the water side. <br />4.1. ASCE 7.16 Seismic Design Information <br />The projectsite is classified as a Site Class F duetothe presence of the liquefiable soils belowlhe proposed <br />buildings. Based on our discussions with PND, it is our understanding that the building vibration period will <br />be less than 0.5 seconds. Consequently, the project can be completed usingthe codebased seismic design <br />per American Society of Civil Engineers (ASCE) 7-16; and a site -specific response analysis Is not required. <br />Based on the previous SPT and CPT borings completed at the site and within the site vicinity, the project <br />site is best characterized as a Site Class D per ASCE 7-16, consistent with the nearby projects along the <br />bulkhead segments A, B, and C (as stated in our draft geotechnical report for Parcels AS, Al2, and A7 dated <br />July 28, 2020) and the Hotel Indigo project, which is approximately 300 feet away from the project site. <br />We recommend the use of the following ASCE 7-16 mapped parameters for Site Class, short Period mapped <br />MCEn spectral response acceleration (S.), 1-second period mapped MCEn spectral response acceleration <br />(Si), and seismic coefficients (FA and Fv) for the project site (Table 1). <br />GEGENGINEEkS.0 Dawtar20 2Ow osrcoge s <br />
The URL can be used to link to this page
Your browser does not support the video tag.