My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
>
Address Records
>
MERRILL CREEK PKY
>
6500
>
BASE FILE
>
6500 MERRILL CREEK PKY BASE FILE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 10:43:21 AM
Creation date
2/18/2024 9:44:15 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6500
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10. Smoke/Aerosol Tester-Smoke detectors will be tested in place using a Smoke ❑ ❑ ❑ <br /> Detector Tester Aerosol Dispenser with Telescoping Pole to ensure smoke entry <br /> into the sensing chamber and an alarm response. No magnets will be allowed. <br /> 11. Laptop- Laptop with appropriate software to make program changes if necessary. ❑ ❑ ❑ <br /> 12. Manufacturer's Testing-Any equipment required by the manufacturer's ❑ ❑ ❑ <br /> published testing instructions. <br /> Notification of Testing: ❑ ❑ ❑ <br /> 13. Occupants-All building occupants shall be notified of the test. ❑ ❑ ❑ <br /> 14. Monitoring Company- Monitoring Company shall place the systems(s) in "test". ❑ ❑ ❑ <br /> 15. Verify Information -Verify that the monitoring company has a valid address, ❑ ❑ ❑ <br /> proper business name, and the correct number for Snohomish County 911 (425- <br /> 407-3970). <br /> Step 2: Signage and Markings PASS FAIL N/A <br /> 1. FACP Room-An approved sign shall be posted on the door to the room containing ❑ ❑ ❑ <br /> the FACP.The sign shall be constructed of durable materials, permanently <br /> installed, readily visible, and have a red background and white lettering that reads <br /> "FIRE ALARM CONTROL PANEL INSIDE" or"FIRE ALARM ROOM" or"FACP ROOM" <br /> or similar language. <br /> 2. Contact Information -An approved sign shall be posted at the control panel and ❑ ❑ ❑ <br /> states the name of the monitoring company and the 24-hour phone number of the <br /> Central Station. It shall also state that the Central Station shall be called before <br /> doing any work or testing on any system being monitored. <br /> 3. Instructions- Reset instructions and reset code shall be clearly posted at the FACP ❑ ❑ ❑ <br /> 4. Floor Plan -A laminated floor plan (11"x17" minimum)for each building floor shall ❑ ❑ ❑ <br /> be posted adjacent to the FACP in the Fire Control Room. It shall indicate the <br /> location of all initiating devices, inspector's test valve, monitored valves and main <br /> corridors, stairwells and elevators. <br /> 5. Dedicated Circuit-The fire alarm control panel shall be on its own dedicated ❑ ❑ ❑ <br /> circuit that is labeled FACP, red in color, and locked in the ON position. <br /> 6. J-Boxes- It is required that all fire alarm J-boxes are painted red or labeled FIRE ❑ ❑ ❑ <br /> ALARM. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 I Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.