My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-92 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-92
>
3003 W CASINO RD BLDG 40-92 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:13:42 AM
Creation date
5/7/2024 11:23:16 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-92
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[2]FIGURE 1.EXPLODED VIEW OF DUCT SMOKE DETECTOR COMPONENTS: <br /> /EXHAUSTTUBE <br /> r 4-WIRE <br /> O POWER BOARD <br /> m POWER BOARD MODULE COVER <br /> 0 <br /> SENSOR MODULE <br /> ° COVER <br /> METAL m / <br /> SAMPLING TUBE <br /> (sold seperately) e <br /> [ <br /> SENSOR HEAD <br /> MAGNET TEST LOCATION e <br /> H0549-06 <br /> [3]GENERAL DESCRIPTION packaged rooftop heating and air-conditioning system, fire/smoke dampers <br /> Smoke introduced into an air duct system will be distributed throughout the and economizers.They may be mounted in either the supply and/or return air <br /> entire building.Smoke detectors designed for use in air duct systems are used section as determined by local code. <br /> to sense the presence of smoke in the duct. Once a suitable location is selected,determine if the detector is to be mounted <br /> Model D4120 and D4S Duct Smoke Detectors utilize 4-wire photoelectric tech- in a side-by-side "rectangular" configuration or a top-over-bottom "square" <br /> nology for the detection of smoke. This detection method, when combined configuration as shown in Figure 2.If mounting in the square configuration, <br /> with an efficient housing, samples air passing through the duct allowing de- remove the rear attachment screw,rotate the unit at the hinge,and replace the <br /> tection of a developing hazardous condition.When sufficient smoke is sensed, screw into the new attachment hole as shown in Figure 2. Do NOT remove <br /> an alarm signal is initiated and appropriate action can be taken to shut off the hinge screw during this process.Final installation approval shall be based <br /> fans, blowers, change over air handling systems, etc. These actions can fa- upon passing section 7.2.2 and/or 8.2.4 tests. <br /> cilitate the management of toxic smoke and fire gases throughout the areas FIGURE 2: <br /> served by the duct system. REMOVE SCREW AND PIVOT REPLACE SCREW <br /> The D4120 and D4P120 detectors are designed to operate on 24 VDC/VAC or DETECTOR AS SHOWN BELOW. TO SECURE DETECTOR <br /> 120 VAC.Alarm and supervisory relay contacts are available for control panel - IN PLACE. <br /> interface(alarm initiation),HVAC control,and other auxiliary functions.Aux- ® m - <br /> iliary relays are provided for fan shut down.Detector interconnection provides <br /> signaling of up to 50 other detectors in the loop for multiple fan shut down. <br /> These detectors are not designed for 2-wire applications. <br /> [3.1]DETECTOR FEATURE SET <br /> -Utilizes 2D51 plug-in head <br /> -2 sensors to 1 power board capability <br /> -Cover missing signal <br /> -Sampling tubes install from front or rear of detector <br /> -Compatible with existing accessories <br /> [4]CONTENTS OF THE DUCT SMOKE DETECTOR KIT H0550-00 <br /> 1. Sensor/power board assembly and cover(s) [5.3]DRILL THE MOUNTING HOLES <br /> 2. Three u10 sheet metal screws for mounting Remove the paper backing from the mounting template supplied. Affix the <br /> template to the duct at the desired mounting location.Make sure the template <br /> 3. Drilling template lies flat and smooth on the duct. <br /> 4. One sampling tube end cap <br /> [5.3.1]FOR RECTANGULAR SIDE-BY-SIDE MOUNTING CONFIGURATION: <br /> 5. One plastic exhaust tube Center punch at(4)target centers: (2) "A"for sampling tubes and(2) "B"for <br /> NOTE:A sampling tube must be ordered to complete the installation.It must the rectangular configuration mounting tabs as shown on mounting template. <br /> be the correct length for the width of the duct where it will be installed. Drill pilot holes at target "A" centers and cut two 1.375 inch diameter holes <br /> See Table 1 on page 3 to determine the inlet tube required for different duct using a 13/8 inch hole saw or punch.Drill.156 inch diameter holes using a 5/32 <br /> widths. inch drill at target"B"centers. <br /> [5]DETECTOR INSTALLATION [5.3.2]FOR SQUARE TOP-OVER-BOTTOM MOUNTING CONFIGURATION <br /> [5.1]VERIFY AIR FLOW DIRECTION AND VELOCITY OR D4S SENSOR COMPONENT MOUNTING: <br /> Model D4120 detectors are designed to be used in air handling systems with Center punch at(4)target centers: (2) "A"for sampling tubes and (2) "C"for <br /> air velocities of 100 to 4000 feet per minute.Duct widths from 6 inches to 12 the square configuration mounting tabs as shown on mounting template.Drill <br /> feet can be accommodated. Be sure to check engineering specifications to pilot holes at target"A"centers and cut two 1.375 inch diameter holes using <br /> ensure that the air velocity in the duct falls within these parameters.If neces- a 13/8 inch hole saw or punch.Drill.156 inch diameter holes using a 5/32 inch <br /> sary,use a velocity meter(anemometer)to check the air velocity in the duct. drill at target"C"centers. If desired, drill an additional .156 inch hole at the <br /> [5.2]DETERMINE MOUNTING LOCATION AND CONFIGURATION location of one of the mounting tabs on the lower housing. <br /> On ducts wider than 18 inches it is recommended that the detector be [5.4]SECURE THE DUCT DETECTOR TO THE DUCT <br /> mounted downstream of a bend, obstruction in the duct, or the supply or Use two(rectangular configuration)or three(square configuration)of the pro- <br /> return air inlet. vided sheet metal screws to screw the duct detector to the duct. <br /> Exception: Installation of duct detectors can be on or within a commercial CAUTION:Do not overtighten the screws. <br /> 2 156-2967-008R <br /> 06-10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.