10524 13TH AVE W 2024-12-02
>
Address Records
>
13TH AVE W
>
10524
>
10524 13TH AVE W 2024-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2024 2:19:14 PM
Creation date
5/14/2024 3:45:54 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH AVE W
Street Number
10524
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> 74-irg.? PUBLIC WORKS <br /> iii. Sheet 4 of 7 <br /> iv. Sheet 5 of 7 <br /> v. Sheet6of7 <br /> vi. Sheet 7 of 7 <br /> vii. Indicate with your resubmittal that you have coordinated/are coordinating with <br /> Mukilteo Water and Wastewater District for the sewer stub connection locations. <br /> Label each main with the appropriate purveyor on the plans, sheet 6. <br /> 2. The comments below were generated from this project's Stormwater Reviewer. If you have any <br /> questions regarding these comments, please contact Jane Zimmerman with the City of Everett <br /> Public Works Department/Drainage Review(JZimmerman@everettwa.gov). <br /> a. DRAINAGE REPORT (Stormwater Site Plan) <br /> i. The project will trigger City standards for additional requirements for <br /> redevelopment sites. The report references a section of Ordinance 3168-10 to <br /> exempt the project from additional requirements due to its size (less than an acre). <br /> However, Ordinance 3168-10 was replaced by Ordinance 3528-16, which <br /> eliminated the 1 acre threshold. The City's current additional requirements for <br /> redevelopment projects language is codified in EMC 14.28.040, which reads as <br /> follows: <br /> 14.28.040 Additional requirements for redevelopment project sites. <br /> A. For road-related projects, runoff from the replaced and new hard surfaces <br /> (including pavement,shoulders,curbs,and sidewalks)and the converted vegetated <br /> areas shall meet all minimum requirements if the new hard surfaces total five <br /> thousand square feet or more and total fifty percent or more of the existing hard <br /> surfaces within the project limits. The project limits shall be defined as the length <br /> of the project and the width of the right-of-way. <br /> B. Other types of redevelopment projects shall comply with all the Minimum <br /> Requirement Nos. 1 through 9 for the new and replaced hard surfaces and the <br /> converted vegetated areas if the total of the new plus replaced hard surface is five <br /> thousand square feet or more and the valuation of the proposed improvements, <br /> including interior improvements,exceeds fifty percent of the assessed value of the <br /> existing site improvements. (Ord. 3528-16 § 3 (part), 2016: Ord. 3168-10 § 3 <br /> (part), 2010) <br /> ii. MR#2: Construction Stormwater Pollution Prevention Plan(SWPPP) <br /> • In the narrative for Element 7, reference BMP C220: Storm Drain Inlet <br /> Protection. <br /> • In the narrative for Element 9, reference BMP Cl 51: Concrete Handling <br /> and BMP C154: Concrete Washout Area. <br /> • In the narrative for Element 10, reference BMP C236: Vegetative <br /> Filtration. <br /> • In the narrative for Element 11,reference BMP C150: Materials On Hand. <br /> • In the narrative for Element 12, reference BMP C 150: Materials On Hand <br /> and CMP C162: Scheduling. <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.