My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-07-07
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-07-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2025 10:24:40 AM
Creation date
7/19/2024 1:10:31 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
543
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Eric Evans <br />Shelter Holdings <br />Plan Check Number: B1912-032, First Structural Review <br />January 3, 2020 <br />Note that most walls are oriented parallel to the floor joists and will therefore be concentrated <br />on the joists in the proximity of the walls. See IBC Sections 1603.1, 1604.1, and 1604.4. <br />16. The structural calculations for the wood roof framing appear to only consider the dead and <br />snow loads of 15 psf and 25 psf, respectively. The Roof Loading Diagrams on Sheets S4.5113 <br />and S4.5213 specify additional superimposed dead loads for solar panels (15 psf), overframing <br />(5 psf), and mechanical units (operating weights up to 2,151 Ibs per Sheets MB002 and <br />MB003). These additional loads do not appear to be included in the roof weight estimate or the <br />framing calculations. In addition, the framing plans do not appear to include additional or <br />stronger framing in the areas where the superimposed loads occur. The design of the roof <br />framing should be reviewed and revised as needed. Revised calculations substantiating the <br />design of the framing should be submitted for review. See IBC Sections 1603.1, 1604.1, and <br />1604.4. <br />17. The roofing framing at Grid B.3-D.3/14.2-18.5 on Sheet S4.4213 is specified as multi -span Type <br />1-5, which the Joist Schedule identifies as 9 1/2 TJI 230 at 12-inch spacing. The representative <br />calculation for the Type 1-5 joist appears to be "RI-5", which considers a single -span 11 7/8 TJI <br />110 at 24-inch spacing. The total joist loading appears to be 40 psf for both dead and snow <br />loading, whereas the roof weight estimate appears to be 40 psf without snow. Revised <br />structural calculations substantiating the roof framing should be submitted for review. The <br />design should be revised as needed. See IBC Sections 1603.1, 1604.1, and 1604.4. <br />Lateral System: <br />18. The geotechnical report by HWA Engineers, Inc., dated March 19, 2019, states in Section 4.2.1 <br />that the project site soils are classified as Site Class F. It further states that the structural <br />design may be performed using seismic design coefficients corresponding to Site Class D. The <br />building must be shown to have a building period of 0.5 seconds or less in accordance with <br />ASCE 7-10 Section 20.3.1. Calculations determining the fundamental building periods for each <br />principal direction shall be submitted for review. Calculation of the building period per Section <br />12.8.2.1, as included in the FEM analysis in the structural calculations, shall not be used to <br />satisfy this requirement. The piles are part of the lateral force resisting system and provide <br />significant flexibility to the structure, and shall be considered in determining the building <br />periods; the period analyses shall not be limited to the portion of the structure above the Level <br />1 slab. See IBC Section 1613.1. <br />19. The grade beam design in Detail 11/S6.04 appears to comply with the requirements of IBC <br />Section 1810.3.12 and ACI 318-14 Sections 18.13.3.2. The grade beams provide rotational <br />restraint for the piles that form part of the lateral force resisting system (LFRS) for the building, <br />and therefore the grade beams are also part of the LRFS. The grade beams should be designed <br />considering the criteria of ACI 318-14 Sections 18.13.3 and 18.6. Alternatively, the grade <br />beams should be designed per IBC Section 1810.3.12 and ASCE 7-10 Section 12.4.3.2. <br />20. The wood shear wall calculations have been performed considering douglas-fir/larch (DFL) <br />framing. Similarly, the shear wall schedule in Detail 6/S1.02 indicates DFL lumber. However, <br />3200 <br />dar <br />0 Everett WAStreet98201 O 425.257.88577 fax O everett asgov/permitgov <br />s <br />Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.