Laserfiche WebLink
Shyamal Gounder <br />Shyvani Investments LLC <br />Plan Check Number: B2103-052, First Building Review <br />August 16, 2021 <br />20. It appears that Detail 5 on Sheet A-3 may have had a printing issue due to not being able to <br />see dimensions that are referenced. R106.1.1 <br />21. It appears that the upper roof located between Grid Lines 3 and 4 is still present on Sheet A-8. <br />22. It is unclear how the Roof Deck is accessed. In Section 2 on Sheet A-9 a glazed roof access is <br />specified but no information is shown on the Roof Deck Floor Plan. Plans should be coordinated <br />with Structural drawings to show framing requirements. R106.1.1 <br />23. See Section 2 on Sheet A-9. It appears that the headroom in the stairway is less than 6 feet 8 <br />inches. R311.7.2 <br />24. It appears that the fireplace on the Main Floor conflicts with the window well in ADU Bedroom <br />1. The Basement Level Floor Plan shows the fireplace about 14'-6" away from Grid Line 3 but <br />on the Main Level Floor Plan shows the fireplace 10'-5" away from Grid Line 3. R310.2.3 <br />25. It appears that Sheet A-11 is missing. R106.1.1 <br />26. Structural information provided in Architectural drawings duplicate and conflict with Structural <br />drawings. Architectural drawings should include a note to specify that Structural notes control. <br />R106.1.1 <br />(S 3200 Cedar Street <br />Everett, WA 98201 <br />© 425.257.8810 O <br />425.257.8857 fax <br />everetteps@everettwa.gov <br />everettwa.gov/perm its <br />Page 4 of 8 <br />