My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2024-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2024 11:33:02 AM
Creation date
8/5/2024 10:36:48 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- FARRINGTON <br /> ,7_,..r---== AIR QUALITY SERVICES <br /> Air Handling Unit <br /> PROJECT: Ballot Facility TI DATE: 6/17/2024 <br /> LOCATION: Everett,WA CONTACT: JT Parker <br /> PROJECT#: 23-1064 <br /> SYSTEM/UNIT: AHU-01/B-29 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 700 CFM <br /> Model Number VDDF Actual Max Airflow 670 CFM <br /> Serial Number R23K01762 Max Diff.SP 0.50 in.wc <br /> Box Inlet Size 08/06 Min Design CFM 210 CFM <br /> K Factor 2.08/2.18 Actual Min Airflow 205 CFM <br /> Min Diff.SP 0.05 in.wc <br /> Design Reheat Airflow 490 CFM <br /> Actual Reheat Airflow 470 CFM <br /> Reheat Diff.SP 0.83 in.wc <br /> AHU-01/B-29 Supply Outlet Summary <br /> System/Unit Outlet Size LxW/ Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM <br /> Outlet-01 CD 24x24 Flowhood 1.00 700 670 670 96 <br /> Totals: - - - - 700 670 670 96 <br /> SYSTEM/UNIT: AHU-01/B-30 Tested By: Eric Liles <br /> Date: 6/17/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Trane Design Max Airflow 1575 CFM <br /> Model Number VDDF Actual Max Airflow 1545 CFM <br /> Serial Number R23K01767 Max Diff.SP 0.53 in.wc <br /> Box Inlet Size 12/08 Min Design CFM 475 CFM <br /> K Factor 2.04/2.02 Actual Min Airflow 475 CFM <br /> Min Diff.SP 0.05 in.wc <br /> Design Reheat Airflow 1100 CFM <br /> Actual Reheat Airflow 1085 CFM <br /> AHU-01/B-30 Supply Outlet Summary <br /> System/Unit Outlet Size LxW I Instrument AK Design Prelim Final CFM %Final <br /> Type D Factor CFM CFM - <br /> Outlet-01 CD 10 Flowhood 1.00 225 225 225 1• 00 <br /> Outlet-02 CD 10 Flowhood 1.00 ' 225 2- 25 225 100 <br /> Outlet-03 CD 10 Flowhood 1.00 225 2- 25 225 100 ' <br /> Outlet-04 CD 10 Flowhood ' 1.00 225 225 225 1• 00 <br /> Outlet-05 CD 10 Flowhood 1.00 ' 225 225 225 - 1• 00 <br /> Outlet-06 CD 10 Flowhood 1.00 225 225 215 96 ' <br /> Outlet-07 CD 10 Flowhood 1.00 225 225 220 98 <br /> Totals: - - - - 1575 1575 1560 99 <br /> Farrington Air Quality Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.