My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • i of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.6.10, Maximum allowable For each fan system serving a multiple-zone <br /> Item 9 system brake VAV HVAC,provide calculations that verify <br /> horsepower fan system electrical input power is<_90%of <br /> the fan power budget in accordance with <br /> Section C403.8.1.1 <br /> C403.6.10, Fan-powered terminal Indicate all series and parallel fan-powered <br /> Item 10 unit motor and terminals have electronically commutated <br /> control motors(ECM);indicate DDC control system <br /> is configured to vary air terminal fan speed as <br /> a function of the load;indicate fan speed <br /> during periods of low heating,low cooling,or <br /> ventilation-only mode is<66%of peak <br /> design air flow,or provide supporting <br /> documentation for applied exception <br /> C403.6.10, Application of single Indicate VAV terminal types on plans;verify <br /> Item 11 duct and fan-powered fan-powered terminal units only serve <br /> terminal units perimeter zones with envelope loads and <br /> interior zones with high occupant density and <br /> DCV per C403.7.1;verify all other zones are <br /> served by single duct terminal units <br /> C403.6.10, Fan-powered terminal Indicate DDC controls are configured to <br /> Item 12 unit primary air reset automatically reset the primary supply air cfm <br /> setpoint of all fan-powered terminal units to <br /> the minimum required to maintain ventilation <br /> during occupied heating or deadband mode, <br /> based upon the VAV air handling unit <br /> minimum ventilation air fraction <br /> C403.6.10, Controls for high For zones> 150 sf with high occupant density <br /> Item 13 occupant density (>_25 people/1000 sf),indicate zone is <br /> spaces served by a dedicated terminal unit with DCV <br /> control that resets terminal unit ventilation <br /> setpoint based on measured CO2;also <br /> indicate occupancy sensor control that <br /> automatically reduces minimum ventilation to <br /> zero and sets back room heating and cooling <br /> setpoints by>_5°F when space in unoccupied <br /> C403.6.10, Dedicated cooling For data centers and server,electronic <br /> Item 14 systems serving data equipment,telecom or similar spaces with <br /> centers and server, design cooling loads>5 W/sf,indicate spaces <br /> electronic equipment are served by dedicated cooling systems that <br /> and telecom spaces are independent of the HPVAV systems <br /> serving the rest of building <br /> C403.6.10, Dedicated cooling Indicate dedicated cooling systems are <br /> Item 14 systems serving data configured for 100%air economizer <br /> centers and server, operation and comply with all related <br /> electronic equipment economizer requirements per C403.5(without <br /> and telecom spaces economizer exceptions),or heat recovery per <br /> C403.5,Exception 9 <br /> C403.6.10, Central plant Indicate whether systems are served by a high <br /> Item 15 efficiency efficiency heating water plant,or a high <br /> efficiency chilled water plant <br /> Page 28132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.