My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.6.10, Central plant if complying via high efficiency heating water <br /> Item 15 efficiency plant:Indicate all VAV terminals have <br /> hydronic heating coils served by a heating <br /> water system with either gas-fired boiler(s) <br /> with thermal efficiency(Et)Z 92%,air-to- <br /> water heat pumps,or heat recovery chillers; <br /> indicate hydronic heating coils are sized per a <br /> maximum 120°F entering water temperature <br /> during peak demand <br /> C403.6.10, Central plant If complying via high efficiency chilled water <br /> Item 15 efficiency plant:Indicate all VAV air handlers have <br /> cooling coils served by chillers with rated <br /> IPLV efficiency that exceeds WSEC listed <br /> IPLV by at least 25%per Table C403.3.2(7) <br /> (note water-cooled IPLV is max,all others are <br /> min);indicate smallest chiller or compressor <br /> in plant is<20%of the total plant capacity, <br /> or provide thermal storage sized for>20%of <br /> total plant capacity <br /> C403.6.10, Fault detection and Indicate DDC system includes automatic fault <br /> Item 16 diagnostics detection and diagnostics(FDD)configured <br /> to monitor operation and provide fault <br /> reporting of all required parameters for all <br /> VAV air handlers and VAV air terminal units <br /> in the HPVAV system <br /> HIGH EFFICIENCY SINGLE-ZONE VAV SYSTEMS-EXCEPTION TO C403.3.5 DOAS,MUST COMPLY WITH ALL 8 PROVISIONS TO <br /> BE ELIGIBLE <br /> C403.12, Air economizer Indicate system is configured for 100%air <br /> Item 1 economizer operation and complies with all <br /> related economizer requirements per C403.5 <br /> (without economizer exceptions) <br /> C403.12, Direct digital controls Provide DDC controls for all components of <br /> Item 2 (DDC) system per C403.4.11 (regardless of system <br /> size);identify all DDC system input/output <br /> control points;indicate capability for trending <br /> and graphical display <br /> C403.12, Outdoor airflow For systems with minimum required outdoor <br /> Item 3 measurement and air> 1,000 cfm,provide an airflow <br /> control monitoring station that is configured to <br /> measure outdoor air intake under all load <br /> conditions;indicate controls that adjust <br /> outdoor air cfm via DCV per C403.7.1 <br /> C403.12, Maximum allowable For each fan system serving a single-zone <br /> Item 4 fan power VAV system,provide calculations that verify <br /> fan system electrical input power is<_90%of <br /> the fan power budget in accordance <br /> withC403.8.1.1 <br /> C403.12, Supply airflow Provide controls that adjust supply airflow <br /> Item 5 control based on the heating and cooling loads; <br /> indicate control sequence that limits minimum <br /> fan speed to 30%of peak design airflow or <br /> required ventilation during unoccupied mode, <br /> whichever is less <br /> Page 29132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.