My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
>
Address Records
>
SW EVERETT MALL WAY
>
210
>
BASE FILE
>
210 SW EVERETT MALL WAY BASE FILE 2024-10-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2024 1:45:46 PM
Creation date
9/16/2024 3:50:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
210
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.12, Controls for high For zones> 150 sf with high occupant density <br /> Item 6 occupant density (>_25 people/1000 sf),indicate DCV control <br /> spaces that resets ventilation setpoint based on <br /> measured CO2;also indicate occupancy <br /> sensor control that automatically reduces <br /> minimum ventilation to zero and sets back <br /> room heating and cooling setpoints by>_5°F <br /> when space in unoccupied <br /> C403.12, High efficiency Indicate which system performance option is <br /> Item 7 system option applied-high efficiency DX cooling and heat <br /> pump or high efficiency gas heating;or <br /> heating coils served by a high efficiency <br /> heating water plant;or cooling coils served by <br /> high efficiency chilled water plant <br /> C403.12, High efficiency If complying via high efficiency DX:Indicate <br /> Item 7 system option full load and part load rated cooling efficiency <br /> exceeds WSEC listed efficiency by at least <br /> 15%;if heating is supplied by a gas-fired <br /> furnace,indicate thermal efficiency(Et)is>_ <br /> 90%;if system is a heat pump,indicate <br /> heating efficiency(HSPF or COP)exceeds <br /> WSEC listed efficiency by at least 10%; <br /> control of cooling and heating coil output shall <br /> be configured with a minimum of 2-stages or <br /> modulating <br /> C403.12, High efficiency If complying via high efficiency heating water <br /> Item 7 system option plant:Indicate hydronic heating coils are <br /> served by a heating water system with either <br /> gas-fired boiler(s)with thermal efficiency <br /> (Et)>92%,air-to-water heat pumps,or heat <br /> recovery chillers;indicate hydronic heating <br /> coils are sized per a maximum 120°F entering <br /> water temperature during peak demand <br /> C403.12, High efficiency If complying via high efficiency chilled water <br /> Item 7 system option plant:Indicate cooling coils are served by <br /> chillers with rated IPLV efficiency that <br /> exceeds WSEC listed IPLV by at least 25% <br /> per Table C403.3.2(7)(note water-cooled <br /> IPLV is max,all others are min);indicate <br /> smallest chiller or compressor in plant is<_ <br /> 20%of the total plant capacity,or provide <br /> thermal storage sized for>_20%of total plant <br /> capacity <br /> C403.12, Fault detection and Indicate DDC system includes automatic fault <br /> Item 8 diagnostics detection and diagnostics(FDD)configured <br /> to monitor operation and provide fault <br /> reporting of all required parameters for all <br /> HPVAV single-zone air systems <br /> EXTERIOR HEATING SYSTEMS <br /> C403.11.1 Heating outside a Indicate systems providing hearing in non- <br /> building enclosed outdoor occupied spaces are radiant <br /> systems <br /> Page 30132 <br />
The URL can be used to link to this page
Your browser does not support the video tag.