3928 FRIDAY AVE 2024 Plans 2024-09-25
>
Address Records
>
FRIDAY AVE
>
3928
>
Plans
>
3928 FRIDAY AVE 2024 Plans 2024-09-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 10:29:13 AM
Creation date
9/25/2024 10:29:02 AM
Metadata
Fields
Template:
Address Document
Street Name
FRIDAY AVE
Street Number
3928
Permit
B2403-103
Year
2024
Notes
INSTALL (10) HELICALS TO STABILIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOUNDATION NOTES 1 s <br /> 1. VERIFY ALL DIMENSIONS ON SITE. <br /> 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER MR LEVEL SURVEY. <br /> 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: I u' • <br /> !ry <br /> HELICAL PILE..............................................11S0-I.1 rsi <br /> HELICAL PILE WI L6x6x3/8 ANGLE............21SD-1.1 • - <br /> 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED MARCH 4TH,2024,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND REQUIREMENTS. 1 5, 00 <br /> 5. LEVEL SURVEY PER RV REPAIR PLAN DATED SEPTEMBER 25TH,2023.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL4AN*‘1°" . -t I4 <br /> REQUIREMENTS FOR REPAIR PLAN. <br /> 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8°. LX =Existing Post <br /> 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0'-6'TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING 2x8 4 Z'on enter <br /> PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. X ,.{ <br /> B. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8'THICK MINIMUM WITH 2'-8'HEIGHT(MEASURED FROM B/FTG TO 0) y =3"Helical Pile <br /> TICONC)MINIMUM. 1 CD <br /> CO <br /> 9. PARCEL AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER KING COUNTY IMAP.NOT TO BE USED FOR LEGAL PURPOSES. Oa * =New Post <br /> 10.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. 'cc LOCATE PILES UNDER -1 W <br /> 11.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"(UNO PER GEOTECHNICAL REPORT). C": BUNDLED KING&JACK _ <br /> STUDS CARRYING GARAGE N >0 - c <br /> HELICAL PILE REFUSAL CRITERIA Yc_ DOOR HEADER I -1 z <br /> TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY D <br /> FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. -I -2 1/• I I— j ' <br /> z <br /> Es <br /> SITE PLAN LEGEND C ' N Z z <br /> PILE SPACING&LOAD REQUIREMENTS TABLE -2t (3)PiLES. j"'� Q'w <br /> EXISTING RESIDENCE STRUCTURE MAX Q.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips * .1 I 6-0'OC MAX lJJ <br /> PILE# PILE TYPE 200%MIN VERTICAL LOCATION 6'0.' t�t <br /> EXISTING ADJACENT STRUCTURE BTWN PILES END OFFSET ALLOWABLE LOADING CAPACITY _I L WITHIN LE <br /> OC MAX I <br /> . <br /> 3'C I <br /> (MIN ULTIMATE CAPACITY) FROM CORNER <br /> AREA OF PROPOSED WORK I b,,/ 4 <br /> "I �/� <br /> PROPERTY LINE 3,8-10 HELICAL 6'-0" PER PLAN 9.0 k/PILE 16.0 k/PIL44 <br /> E EXT/INT Q 5i22' 6 <br /> 4-7 12.0 k/PILE 24.0 k/PILE EXT/INT �((, ;q;PILES 6'0'OC MAX <br /> ---- APPROXIMATE DIMENSION NOTES: <br /> HELICAL PILE a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE , <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> Mil L6x6x3/8 ANGLE EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM R&R LEVEL SURVEY <br /> INSTALLATION TORQUE RATING OF 8,300FT•LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> THICKNESS PER ESR-3750. See Structural Calculation Package for Additional Requirements <br /> Ct NEW POST b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" <br /> TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. _ <br /> c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. <br /> d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART <br /> OF THE ASSEMBLY. <br /> e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. <br /> 3928 FRIDAY AVE SE <br /> EVERETT <br /> PROPERTY LINE •�•�•�•� _ 10 9 8 •-- WA98201 <br /> i.—.—.—"_._.—.—"—.—.—.—.—._. ._._._.—.—._.—._.—._._.—._.—._._•723'-0^_._.—.—.—.—.—. .—.—._._.— •32,_6,. _..y •—•—•—•—.—.—._._._.�._._._._.�._._._ i <br /> } i S240104-1XR <br /> o I JT <br /> I PARCEL NO. },i`--5'-6" ,�. 7 6 i MRT <br /> I 00470700401500 03/04/2024 <br /> I LEGAL DESCRIPTION 2 .. 33 <br /> HEWITT HEIGHTS ADD TO EVERETT - - - AYA N I 0 <br /> I� BLK 004 D-0O-LOT 15 RESIDENCE <br /> AVE SE VAV VIA <br /> wr I OWNER NAME 8 ADDRESS EVERETT,WA 98201 .0.5 c I. <br /> •'•Xi MCCOLM HEATHER/ROBINSON DAVID — z <br /> 3928 FRIDAY AVE SE <br /> EVERETT,WA 98201 I m <br /> IA o <br /> I4 <br /> I I <br /> 1 + I <br /> I I <br /> k 38'D„ <br /> I 1 2 <br /> I ._.—"_._..—._.—.PROPERTY LINE "_.—.—.._.—.—"—.—.—"—.—.—"—._..__.—.—"_.—.—.—.—.—.—.—.—"_._..—.—._..—.—.—.—.—.—.—.—.— —._. <br /> .—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—.�.—.—. 123'0„' A <br /> cc iU <br /> C Q a< Q <br /> _1NJ <br /> CL UT <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN H= <br /> Ln <br />