Commissioning Plan Page 23 <br /> 3. Review design for provision of manual balancing/volume dampers, control <br /> dampers, and controls connections. <br /> 4. Provide TAB Contractor's submittals as specified in section 23 05 93, including <br /> but not limited to the following. Revise as necessary per Cx team review <br /> comments. <br /> a) Qualifications of the lead TAB technician for the project, including the name <br /> and contact information of recent projects performed by the technician. <br /> b) TAB Plan (or TAB Agenda), describing the test and balance procedure for <br /> each system and component. Include blank equipment-specific TAB forms <br /> to be utilized on this project. The CA shall review the TAB plan and <br /> comment for any required changes to facilitate the commissioning process. <br /> The plan shall include: <br /> i. Description of system test procedures to verify system is ready for TAB. <br /> ii. Sample test report forms to be used. <br /> iii. Detailed step-by-step procedures for TAB work for each system. <br /> iv. List of all air flow, water flow, sound level, system capacity and <br /> efficiency measurements to be performed and a description of specific <br /> test procedures, parameters, formulas to be used. <br /> v. Details of how total flow will be determined (Air: sum of terminal flows <br /> via BAS calibrated readings or via hood readings of all terminals, supply <br /> (SA) and return air (RA) pitot traverse, SA or RA flow stations. Water: <br /> pump curves, circuit setter, flow station, ultrasonic, etc.). <br /> vi. The identification and types of measurement instruments to be used <br /> and their most recent calibration date. <br /> vii. Specific procedures that will ensure that both air and water side are <br /> operating at the lowest possible pressures and provide methods of <br /> verification <br /> viii. Confirmation that TAB understands the outside air ventilation criteria <br /> under all conditions. <br /> ix. Details of how building static and exhaust fan / relief damper capacity <br /> will be checked. <br /> x. Proposed selection points for sound measurements and sound <br /> measurement methods. <br /> A. Details of methods for making any specified coil or other system plant <br /> capacity measurements. <br /> xii. Details of any TAB work to be done in phases (by floor, etc.), or of <br /> areas to be built out later. <br /> xiii. Details regarding specified deferred or seasonal TAB work. <br /> xiv. Details of any specified false loading of systems to complete TAB. <br /> xv. Details of all exhaust fan balancing and capacity verifications. <br /> xvi. Room pressure differential cascade / map. <br /> xvii. Plan and procedure for duct air leakage testing (DALT). <br /> xviii. Plan for formal daily progress reports, including scope and distribution. <br /> xix. Plan for formal weekly deficiency reports, including scope and <br /> distribution. <br /> xx. Plan for formal TAB reports, including preliminary and final. <br /> 5. Coordinate balancing activities with those of the mechanical and control <br /> contractors. Verify that coordination installation, quality control and final <br /> subcontractor testing have been completed to allow proper work to be performed. <br /> 6. Notify the MC, CA, A/E, and GC/CM/QC as soon as possible of any system <br /> installation or performance issues that may compromise the ability of the system <br /> to be balanced. <br /> 7. Confirm locations of temperature and pressure taps according to the Construction <br /> Documents for controls PVTs, TAB, and CX testing. <br /> Clare's Place Ventilation Revision <br /> IV Neudorfer Engineers, LLC. Page 23 of 68 Everett, WA <br />
The URL can be used to link to this page
Your browser does not support the video tag.