11I 10 AWG THHN/THWN 2.CU„BLACK(0) 10 9 A AC (l► 10 AWG THHN/THWN-2,CU,BLACK Ill) MAX 10.9 A A I I) 10 AWG THHN/THWN-2,CU.,BLACK ILI) MAX 10.9 A A 1) 12.2 TC ER,THHN/THWN 2,CU MAX 10.9 A AC <br /> 1 C (1) 10 AWG THHN/THWN-2,CU.,RED(L2) 240 V AC 3 (1) 10 AWG THHN/THWN-2,CU.RED(L 2) 240 V A 2 {1) 10 AWG THHN/THWN-2,CU.,RED(L2) 240 V A q I I) 6 AWG BARE.CU(EGC) 240 V AC <br /> 7 (1) 10 AWG THHN/THWN-2,CU,,WHI TF IN) (1) 10 AWG THHN/THWN-2,CU,GREEN(EGC) I1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) 1 <br /> (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) OR 10-2 OF-8 W/G,THHN(THWN-2,SOLJD CU OR 10,2 OF-B W/G(OR NM-B),THHN/THWN-2,SOUD CU <br /> I) 3/4 INCH EMI EXTERIOR 11) V4 INCH EMT EXTERIOR (1) 3/4 INCH EMT(Not Required for uF-8 or NM B Cable) INTERIOR EXTERIOR BLUE RAVEN <br /> DESIGNER NOTES: ELECTRICAL NOTES: 1403 N. Research Way <br /> MPU REQUIRED.LOAD SIDE BREAKER IN MSP. EXTERIOR POI. ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. Orem, UT 84097 <br /> 800.377.4480 <br /> W W W.BLUERAVENSOLAR.COM <br /> CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> USED FOR THE BENEFIT OF <br /> (E)200A MAIN SERVICE PANEL EXCEPT BLUE RAVEN SOLAR NOR <br /> E <br /> (E)200A/2P MAIN BREAKER SHALL IT BE DISCLOSED IN WHOLE OR <br /> MAIN SERVICE PANEL TO BE REPLACED IN PART TO OTHERS OUTSIDE <br /> RECIPIENTS ORGANIZATION,EXCEPT <br /> ENPHASE IQ COMBINER 4 IN CONNECTION WITH THE SALE AND <br /> (N)200A MAIN SERVICE PANEL X-IQ-AM1-240-4 USE OF THE RESPECTIVE EQUIPMENT, <br /> (N)200A/2P MAIN BREAKER <br /> (SOLAR LOAD ONLY) WITHOUT THE WRITTEN PERMISSION <br /> OF BLUE RAVEN SOLAR LLC. <br /> PV AC DISCONNECT <br /> (E)200A/2P NON-FUSED <br /> LOCKABLE,VISIBLE OPEN <br /> 30A,240V,2-POLE (9) QCeIIs Q.PEAK DUO BLK ML-G10+395 NABCEP <br /> UL 1703 COMPLIANT <br /> (E)LOADS *PV BREAKER TO BE LOCATED ENVOY (9) Enphase IQ8PLUS-72-2-US CERTIFIED <br /> AT OPPOSITE END OF BUSSING 1�2P UL 1741 COMPLIANT <br /> FROM MAIN BREAKER 4"x4"x4"PVC JB-1 EZ SOLAR <br /> N JUNCTION BOX JUNCTION BOX PV INSTALLATION <br /> (N)20A/2P <br /> L, L, (N)20A/2P L, F JB �L, JB-1 L, (1) CIRCUIT OF PROFESSIONAL <br /> L2 L2 <br /> L2 L2 L2 Scott Gurney <br /> N N — r___ EGC _EGC EGC _ ti 9 MODULES #PV-011719-015866 <br /> ———————————————————————————————————————r——— — ————— ——— ———————————————————————— <br /> G CONTRACTOR: <br /> ti <br /> 120/240 VAC N I J 3 2 1 <br /> 6HA I JUNCTION BOX BRS FIELD OPS <br /> 1 PHASE I OPTIONAL IF OF-B 800-377-4480 <br /> TO UTILITY I CABLE USED FOR <br /> GRID I ENTIRE HOMERUN <br /> G J <br /> U <br /> .. QM Qo <br /> I ► Z � o <br /> (E)GROUNDING <br /> O 4--' CO Y L0 <br /> ELECTRODE(S) I-'- M -- � <br /> Q Co U-) <br /> pnnA g w> o N M <br /> N W. & ool4IIl�rro+�r>� !. o (' u.i u.i <br /> 10 I W > '- N N <br /> ��. of WAS�,� ��� 202103 . 1 — , — z N<, I � W 0 M � <br /> 1 ► � <br /> r a59 CU CW0y, 83 <br /> >. >. <br /> L�l e �aEii t �0 E <br /> � 54072 q, � � � � �� ■ - N <br /> G.t'tS FCISTFR�� 06'00' � FOCUS kWh � � ,►Y '� *. U Y � W Q 0 <br /> —NALE� rr SNOHOMISH COUNTY PUD No-1 DRAWING BY: <br /> 100013949' PremiumCAD <br /> 107 651 902 or- ) PLOT DATE: <br /> •as now aw owe <br /> -ti+• —• March 13, 2023 <br /> INTERCONNECTION NOTES <br /> PROJECT NUMBER: <br /> 705.12(B)(3)THE FOLLOWING METHOD(S)SHALL BE USED TO <br /> DETERMINE THE RATINGS OF BUSBARS: (2)WHERE TWO SOURCES, 722401 <br /> ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SHEET NAME: <br /> SOURCE,ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT <br /> CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE ELECTRICAL <br /> POWER-SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF <br /> THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT REVISION: PAGE NUMBER: <br /> EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. UTILITY COMPANY: Snohomish County Public Utilities District (PUD) PERMIT ISSUER: City of Everett 0 PV5 <br />