My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10705 HOLLY DR 2025-01-23
>
Address Records
>
HOLLY DR
>
10705
>
10705 HOLLY DR 2025-01-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2025 7:39:24 AM
Creation date
11/21/2024 10:01:26 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10705
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• S <br /> 03/03/2017 <br /> Linnyk Residence <br /> Project File Number-C1611-001 <br /> Address: <br /> 10705 HOLLY DR, EVERETT, WA 98204-6204 <br /> Dear, Reviewer <br /> We are writing this letter, so that we may in greater depth explain our response to your requests. <br /> We will attempt to explain how and where you question we addressed. <br /> The changes on the plan were clouded for greater clarity. <br /> 1.The conversion of the Garage into living space requires that the existing walls, windows and <br /> floor meet the minimum requirements of the current Energy Code. R-21 is required in exterior <br /> walls and R-30 is required in the floor. Show how you will meet the requirements of the 2015 <br /> Energy Code on the plans and section drawings. <br /> Response: Area of garage was modified and kept as unheated space. Note clouded <br /> on sheet A04. <br /> 2. Provide R-10 rigid insulation at headers. Show on section drawings. <br /> Response: The header insulation has been shown on section A-A-sheet A-11. <br /> The header insulation detail was provided on sheet 11/AD 1 already. The detail <br /> references posted on section and plans. <br /> 3. Provide insulation baffle over insulation at exterior walls. The baffle shall extended 6 inches <br /> vertically above batt insulation and 12 inches vertically above loose fill insulation. Show <br /> requirement on plans. Maintain minimum 1 inch dear air space over the insulation. <br /> Response: The baffle line have been shown on the section A A-sheet Al 1. <br /> Detail 9/AD 1 provides for roof where was shown baffle over insulation. <br /> Detail references posted on plans and section. <br /> 4. The specific requirements for the Energy Credits from Table 406.2 WSEC shall be shown on <br /> the plans. Do not simply reference the option chosen. <br /> Response: The credit points choices have been revised. The existing duct system <br /> will- extended to the addition for heating the area. We need 1.5credits- as for <br /> additions to existing building that are greater than 500 sqF, but less than 1500 sqF <br /> The note posted on the sheet A07- main floor plan. The note added on sheet A07- <br /> main floor plan. The name of water heater added . <br /> 5. Stair shall comply with section R311 for width and headroom. The modified stairs do not <br /> appear to meet the minimum width requirements. <br /> 1 \5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.