LEGEND <br /> 1 10.5 11 1 1 O SLAB TYPE(SEE NOTES) <br /> CJ CONTROL JOINT <br /> PB PIPE BOLLARD <br /> F GENERAL NOTES <br /> 1 <br /> NEW TWIN DUST COLLECTOR INSTALLATIONS <br /> CONSTRUCTION NOTES <br /> 1. INSTALLATION OF TWO NEW DUST COLLECTORS WILL <br /> w I PROCEED ONCE DAPP ROUTERS ARE INSTALLED,THEN <br /> w/BOEING NOTICE TO PROCEED <br /> z 5 2. OFFSET DIMENSIONS ARE PROPOSED CENTER-TO- <br /> O GRIDLINES,AND CENTER-CENTER DIMENSIONS ARE <br /> Q 1=11 PER CMS(R)LAYOUT'ARES MK2 36/26 APC1 PX5 IT-EN <br /> BL39'PROVISIONAL LAYOUT. <br /> f=1 <br /> z REFERENCE DRAWINGS <br /> 140-053-1201-A6 WIRE SHOP EXPANSION PARTIAL <br /> NEW LAYOUT FIRST FLOOR PLAN <br /> �x x x x X x x x�x - - - - - - - G CMS(R) LAYOUT'ARES MK2 36/26 APC1 PX5 IT EN <br /> BL39'PROVISIONAL LAYOUT <br /> --X----x----x----x----x--J x----x----x----x----x----x----X----X <br /> J -------------------------- -------------------------------------- <br /> LTSA <br /> w <br /> J <br /> (n <br /> x x x x x x x x x x r <br /> � ` EXISTING HVAC SUPPLY y w j I I� ` EXISTING HVA UPPLY <br /> O <br /> Z r ;w wx <br /> ELL <br /> x < F <br /> IFI ROUTER 1 ;2 iOUTER PASSAGEWAY <br /> WAY <br /> w <br /> SMALL PARTS PL - _ - - /'� _ _ _ - - -E- - - - - - - - + - - 1OG11 <br /> z x <br /> \�` - - - - - -�- ROUTER FIRE BID - - j - - \1 <br /> F <br /> E EXTG � <br /> —x x x x x x x x x 1 �, SUPPLY E <br /> T. <br /> PANEL - <br /> H <br /> 6Q.5 Q7 7Q.5 Q8 8Q.5 Q9 9Q.5 1Q0 10.55 1111 <br /> --- --- ---- I I I I I I I I I I <br /> ;- EXTG2'FIRE+18'-2a I I IIAC <br /> --- — --- --a -- -- '-- ---------ojL�CH <br /> --- ------ — R-- ---- 1A10 A <br /> EA OF� _ __ <br /> CO TRUCTION - NRV <br /> ToasraucE HV E JDo ■N v1A11 1Al2Cj _ _ _ _ __ _ _ _- - - -----1 ---------- - - --- --- ----- --1------- <br /> SPRINKLER DEDICATED4"FIRE+16'-4"� SPRINKLER 1A13 1A14 1A15 E <br /> LATERAL - -L---1 -----------F LATERAL__ <br /> j AND DROP CJ -AND DROP N - 1A16 1A17 <br /> DUST COLLECTOR 1 y y DUST COLLECTOR 2 <br /> 1 <br /> I\ J, EXISTING HVAC SUPPLY I\L J/ EXISTING HVAC SUPPLY <br /> L I <br /> 1A19 1A20 1A21 <br /> I I <br /> K <br /> KEY PLAN BLDG.40-53 N <br /> GENERAL ARRANGEMENT PLAN N SCALE:NONE <br /> SCALE: 118"=1'-0" <br /> 13Anthae360 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DALE RabeRA.Mamietluke PE DRAWN DATE SUBTITLE CURRENTREVISiON SYMBOL DATE <br /> ACCEPTABILITY RAM osnenn GENERAL ARRANGEMENT PLAN <br /> THIS DESIGN ANDIRO <br /> CJR <br /> CHECKED W9543149 05128124 <br /> SPECIFICATION IS APPROVED 17109l23 SHEET <br /> ENGINEER TmE A567 <br /> COMP N0. <br /> APPROVED BY DE . DATE DAPP Dust Collector Installation <br /> CHECaD <br /> JOB N0.BUILDING40-053 <br /> A�L%pR� APPROVED <br /> WA PE CE16775 APPROVED DWG no. <br /> ARCHITECTURAL MASTER COL.H.25110.5 EVERETT,WA 40-053-A567 <br />