My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10633 EVERGREEN WAY 2025-01-10
>
Address Records
>
EVERGREEN WAY
>
10633
>
10633 EVERGREEN WAY 2025-01-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2025 9:49:30 AM
Creation date
12/10/2024 2:08:44 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10633
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Concrete and Anchoring: <br /> If you are installing a seismic lift, consult with a structural <br /> engineer and manufacturer's representative for concrete <br /> and anchoring requirements (varies by location). Fig.4 and <br /> the below table apply to non-seismic lifts only. <br /> 1.111.1 <br /> IIIIIIIII� <br /> 11\ INF =am <br /> it•P <br /> AI, le <br /> Drill holes using 3/4" carbide Run nut down just below impact Manually hand tighten <br /> tipped masonry drill bit per section of bolt. Drive anchor nut with torque wrench <br /> ANSI 8212.15-1994(R2000). into hole until nut and washer to 110 ft.-lbs.(149 Nm). <br /> Construction dust collected contact base. <br /> per OSHA 29 CFR 1926.1153. Fig.4 <br /> 10K 2-Post Lift Anchor Installation Reference Guide <br /> Anchor: Min Min Edge Min Anchor Installation Min Concrete PSI Concrete pad Maintenance SEISMIC <br /> Concrete Distance Embedment Anchor Torque Strength-For All Size If Concrete Torque Values** <br /> Thickness (ft-Ibs) Standards Does Not Meet (ft-Ibs) <br /> Requirements <br /> Hilti Kwik Bolt I 4-1/4" 6-1/4" 3-1/4" 110 3000 4'x4'x8" 65 Varies by <br /> (3/4"x 5-1/2") (108mm) (159mm) (83mm) (149Nm) (20684 kPa) (1219 x 1219 x (88Nm) location <br /> 152mm) consult with <br /> your structural <br /> Power-Stud+SD1 4-1/4" 6-1/4" 3-1/4" 110 3000 4'x4'x8" 65 engineer and <br /> (108mm) (159mm) (83mm) (149Nm) (20684 kPa) (1219 x 1219 x (88Nm) manufacturer's <br /> 152mm) representative. <br /> Hilti HY200 5" 2 1/4" 3-1/2" 100)135Nm)/less 3000 4'x4'x8" N/A <br /> Epoxy(with HAS (134mm) (57mm) (89mm) than 2-1/8"edge (20684 kPa) (1219 x 1219 x <br /> threaded rod) distance use 152mm) <br /> 3/4"Dia. Torque Value of <br /> 30 ft-lbs(41 Nm) <br /> *The supplied concrete fasteners meet the criteria of the American National Standard <br /> "Automotive Lifts-Safety Requirements for Construction,Testing,and Validation"ANSI/ALI ALCTV-2011,and the lift owner is responsible for all charges <br /> related to any additional anchoring requirements as specified by local codes.Contact customer service for further information at:800.640.5438 <br /> , � �2. <br />