ZONE FCU-1 <br />Conditions at Time of Space Cooling Peak <br />Conditions at Time of Space Heating Peak <br />Peak Time (Mo/D/H:M) <br />7/21 18:00:00 <br />Peak Time (Mo/D/H:M) <br />12/21 24:00:00 <br />Outside DB / WB / HR <br />75.9 °F / 60.7 °F / <br />55.9 gr/lb <br />Outside DB / WB / HR <br />25.4 °F / 19.1 °F <br />/ 5.9 gr/lb <br />Zone DB / RH / HR <br />75.0 °F / 46.3 % / <br />60.6 gr/lb <br />Zone DB / RH / HR <br />70.0 °F / 7.8 % <br />/ 8.5 gr/lb <br />Time <br />Percent <br />Time <br />Percent <br />Instant <br />Delay <br />of <br />Instant <br />Delay <br />of <br />Sensible <br />Sensible Latent <br />Total <br />Total <br />Sensible <br />Sensible Latent <br />Total <br />Total <br />(Btu/h) <br />(Btu/h) (Btu/h) <br />(Btu/h) <br />(%) <br />(Btu/h) <br />(Btu/h) (Btu/h) <br />(Btu/h) <br />(%) <br />Roof <br />0 <br />1,059 0 <br />1,059 <br />2.5 <br />Roof <br />0 <br />-749 0 <br />-749 <br />6.5 <br />Other Roof <br />0 <br />0 0 <br />0 <br />0.0 <br />Other Roof <br />0 <br />0 0 <br />0 <br />0.0 <br />Glass <br />4,660 <br />26,253 0 <br />30,913 <br />72.0 <br />Glass <br />-4,223 <br />0 0 <br />-4,223 <br />36.4 <br />Door <br />0 <br />0 0 <br />0 <br />0.0 <br />Door <br />0 <br />0 0 <br />0 <br />0.0 <br />Wall <br />0 <br />1,011 0 <br />1,011 <br />2.4 <br />Wall <br />0 <br />-1,017 0 <br />-1,017 <br />8.8 <br />Below -Grade Wall <br />0 <br />0 0 <br />0 <br />0.0 <br />Below -Grade Wall <br />0 <br />0 0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 0 <br />0 <br />0.0 <br />Partition <br />0 <br />-2,475 0 <br />-2,475 <br />-5.8 <br />Partition <br />0 <br />265 0 <br />265 <br />-2.3 <br />Exterior Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Exterior Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Slab <br />0 <br />-1,144 0 <br />-1,144 <br />-2.7 <br />Slab <br />0 <br />-106 0 <br />-106 <br />0.9 <br />Other Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Other Floor <br />0 <br />0 0 <br />0 <br />0.0 <br />Infiltration <br />28 <br />0 -89 <br />-61 <br />-0.1 <br />Infiltration <br />-5,450 <br />0 0 <br />-5,652 <br />48.7 <br />Envelope Subtotal <br />4,688 <br />24,704 -89 <br />29,303 <br />- <br />Envelope Subtotal <br />-9,673 <br />-1,607 0 <br />-11,482 <br />- <br />People <br />4,329 <br />0 4,030 <br />8,359 <br />19.5 <br />People <br />0 <br />0 0 <br />0 <br />0.0 <br />Lights <br />1,423 <br />0 0 <br />1,423 <br />3.3 <br />Lights <br />0 <br />0 0 <br />0 <br />0.0 <br />Miscellaneous Loads <br />3,984 <br />299 0 <br />4,283 <br />10.0 <br />Miscellaneous Loads <br />0 <br />0 0 <br />0 <br />0.0 <br />Internal Subtotal <br />9,736 <br />299 4,030 <br />14,065 <br />- <br />Internal Subtotal <br />0 <br />0 0 <br />0 <br />- <br />RA (All Other) <br />0 <br />0 0 <br />0 <br />0.0 <br />RA (All Other) <br />0 <br />0 0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />0 <br />0 0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />0 <br />0 0 <br />0 <br />0.0 <br />Time Delay Correction <br />0 <br />-448 0 <br />-448 <br />-1.0 <br />Time Delay Correction <br />0 <br />-116 0 <br />-116 <br />1.0 <br />Grand Total <br />14,424 <br />24,556 3,940 <br />42,920 <br />100.0 <br />Grand Total <br />-9,673 <br />-1,723 0 <br />-11,598 <br />100.0 <br />RA Sensible (Lights) <br />0 <br />0 0 <br />0 <br />- <br />RA Sensible (Lights) <br />0 <br />0 0 <br />0 <br />- <br />Engineering Checks <br />Engineering Checks <br />Cooling tons <br />3.58 <br />Input Ventilation cfm <br />119 <br />Heating Mbh <br />-11.60 <br />Input Ventilation cfm <br />119 <br />Cooling cfm <br />1,801 <br />Calculated Ventilation <br />cfm <br />119 <br />Heating cfm <br />1,801 <br />Calculated Ventilation <br />cfm <br />119 <br />Cooling ACH <br />17.36 <br />Calculated Ventilation <br />ACH <br />1.15 <br />Heating ACH <br />17.36 <br />Calculated Ventilation <br />ACH <br />1.15 <br />Sec Fan cfm <br />0 <br />Number of People <br />16.31 <br />Sec Fan cfm <br />0 <br />Number of People <br />16.31 <br />ft2/ton <br />133.03 <br />People per 1000 ft2 <br />34 <br />ft2/Mbh <br />-41.02 <br />People per 1000 ft2 <br />34 <br />cfm/ton <br />503.47 <br />Conditioned ft2 <br />475.8 <br />cfm/Mbh-155.29 <br />Conditioned ft2 <br />475.8 <br />Btu/h-ft2 <br />90.21 <br />Volume (ft3) <br />6,224.6 <br />Btu/h-ft2 <br />-24.38 <br />Volume (ft3) <br />6,224.6 <br />Alternative: Primary Calculated at: Feb 28, 2024 - 12:09 PM <br />File EDWARD JONES, EVERETTE, WA.mdf TRACE 3D Plus 5.20.117 <br />name: <br />