My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ZONE FCU-2 <br />Conditions at Time of Space Cooling Peak <br />Peak Time (Mo/D/H:M) <br />7/21 17:00:00 <br />Outside DB / WB / HR <br />77.8 °F / <br />61.4 °F <br />/ 55.9 gr/lb <br />Zone DB / RH / HR <br />75.0 °F / <br />46.8 % <br />/ 61.4 gr/lb <br />Time <br />Percent <br />Instant <br />Delay <br />of <br />Sensible <br />Sensible <br />Latent <br />Total <br />Total <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(%) <br />Roof <br />0 <br />2,891 <br />0 <br />2,891 <br />12.6 <br />Other Roof <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Glass <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Door <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Wall <br />0 <br />50 <br />0 <br />50 <br />0.2 <br />Below -Grade Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Partition <br />0 <br />3,196 <br />0 <br />3,196 <br />13.9 <br />Exterior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Slab <br />0 <br />2 <br />0 <br />2 <br />0.0 <br />Other Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Infiltration <br />17 <br />0 <br />-21 <br />-4 <br />0.0 <br />Envelope Subtotal <br />17 <br />6,138 <br />-21 <br />6,134 <br />- <br />People <br />3,361 <br />0 <br />2,591 <br />5,952 <br />26.0 <br />Lights <br />4,152 <br />0 <br />0 <br />4,152 <br />18.1 <br />Miscellaneous Loads <br />6,737 <br />0 <br />0 <br />6,737 <br />29.4 <br />Internal Subtotal <br />14,250 <br />0 <br />2,591 <br />16,841 <br />- <br />RA (All Other) <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Time Delay Correction <br />0 <br />-43 <br />0 <br />-43 <br />-0.2 <br />Grand Total <br />14,267 <br />6,095 <br />2,570 <br />22,932 <br />100.0 <br />RA Sensible (Lights) <br />0 <br />0 <br />0 <br />0 <br />- <br />Engineering Checks <br />Cooling tons <br />1.91 <br />Input Ventilation cfm <br />151 <br />Cooling cfm <br />940 <br />Calculated Ventilation cfm <br />151 <br />Cooling ACH <br />3.04 <br />Calculated Ventilation ACH <br />0.49 <br />Sec Fan cfm <br />0 <br />Number of People <br />13.51 <br />ft2/ton <br />743.03 <br />People per 1000 ft2 <br />10 <br />cfm/ton <br />491.87 <br />Conditioned ft2 <br />1,419.8 <br />Btu/h-ft2 <br />16.15 <br />Volume (ft3) <br />18,574.5 <br />Conditions at Time of Space Heating Peak <br />Peak Time (Mo/D/H:M) <br />12/21 24:00:00 <br />Outside DB / WB / HR <br />25.4 °F / <br />19.1 °F <br />/ 5.9 gr/lb <br />Zone DB / RH / HR <br />70.0 °F / <br />8.1 % <br />/ 8.9 gr/lb <br />Time <br />Percent <br />Instant <br />Delay <br />of <br />Sensible <br />Sensible <br />Latent <br />Total <br />Total <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(%) <br />Roof <br />0 <br />-2,340 <br />0 <br />-2,340 <br />30.1 <br />Other Roof <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Glass <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Door <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Wall <br />0 <br />-344 <br />0 <br />-344 <br />4.4 <br />Below -Grade Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Partition <br />0 <br />-2,796 <br />0 <br />-2,796 <br />36.0 <br />Exterior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Slab <br />0 <br />-421 <br />0 <br />-421 <br />5.4 <br />Other Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Infiltration <br />-1,120 <br />0 <br />0 <br />-1,169 <br />15.0 <br />Envelope Subtotal <br />-1,120 <br />-5,901 <br />0 <br />-7,070 <br />- <br />People <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Lights <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Miscellaneous Loads <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Internal Subtotal <br />0 <br />0 <br />0 <br />0 <br />- <br />RA (All Other) <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />-685 <br />0 <br />0 <br />-685 <br />8.8 <br />Time Delay Correction <br />0 <br />-19 <br />0 <br />-19 <br />0.2 <br />Grand Total <br />-1,805 <br />-5,920 <br />0 <br />-7,774 <br />100.0 <br />RA Sensible (Lights) <br />0 <br />0 <br />0 <br />0 <br />- <br />Engineering Checks <br />Heating Mbh <br />-7.77 <br />Input Ventilation cfm <br />151 <br />Heating cfm <br />940 <br />Calculated Ventilation cfm <br />151 <br />Heating ACH <br />3.04 <br />Calculated Ventilation ACH <br />0.49 <br />Sec Fan cfm <br />0 <br />Number of People <br />13.51 <br />ft2/Mbh <br />-182.64 <br />People per 1000 ft2 <br />10 <br />cfm/Mbh <br />-120.93 <br />Conditioned ft2 <br />1,419.8 <br />Btu/h-ft2 <br />-5.48 <br />Volume (ft3) <br />18,574.5 <br />Alternative: Primary Calculated at: Feb 28, 2024 - 12:09 PM <br />File EDWARD JONES, EVERETTE, WA.mdf TRACE 3D Plus 5.20.117 <br />name: <br />
The URL can be used to link to this page
Your browser does not support the video tag.