ZONE FCU-2 <br />Conditions at Time of Space Cooling Peak <br />Peak Time (Mo/D/H:M) <br />7/21 17:00:00 <br />Outside DB / WB / HR <br />77.8 °F / <br />61.4 °F <br />/ 55.9 gr/lb <br />Zone DB / RH / HR <br />75.0 °F / <br />46.8 % <br />/ 61.4 gr/lb <br />Time <br />Percent <br />Instant <br />Delay <br />of <br />Sensible <br />Sensible <br />Latent <br />Total <br />Total <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(%) <br />Roof <br />0 <br />2,891 <br />0 <br />2,891 <br />12.6 <br />Other Roof <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Glass <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Door <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Wall <br />0 <br />50 <br />0 <br />50 <br />0.2 <br />Below -Grade Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Partition <br />0 <br />3,196 <br />0 <br />3,196 <br />13.9 <br />Exterior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Slab <br />0 <br />2 <br />0 <br />2 <br />0.0 <br />Other Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Infiltration <br />17 <br />0 <br />-21 <br />-4 <br />0.0 <br />Envelope Subtotal <br />17 <br />6,138 <br />-21 <br />6,134 <br />- <br />People <br />3,361 <br />0 <br />2,591 <br />5,952 <br />26.0 <br />Lights <br />4,152 <br />0 <br />0 <br />4,152 <br />18.1 <br />Miscellaneous Loads <br />6,737 <br />0 <br />0 <br />6,737 <br />29.4 <br />Internal Subtotal <br />14,250 <br />0 <br />2,591 <br />16,841 <br />- <br />RA (All Other) <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Time Delay Correction <br />0 <br />-43 <br />0 <br />-43 <br />-0.2 <br />Grand Total <br />14,267 <br />6,095 <br />2,570 <br />22,932 <br />100.0 <br />RA Sensible (Lights) <br />0 <br />0 <br />0 <br />0 <br />- <br />Engineering Checks <br />Cooling tons <br />1.91 <br />Input Ventilation cfm <br />151 <br />Cooling cfm <br />940 <br />Calculated Ventilation cfm <br />151 <br />Cooling ACH <br />3.04 <br />Calculated Ventilation ACH <br />0.49 <br />Sec Fan cfm <br />0 <br />Number of People <br />13.51 <br />ft2/ton <br />743.03 <br />People per 1000 ft2 <br />10 <br />cfm/ton <br />491.87 <br />Conditioned ft2 <br />1,419.8 <br />Btu/h-ft2 <br />16.15 <br />Volume (ft3) <br />18,574.5 <br />Conditions at Time of Space Heating Peak <br />Peak Time (Mo/D/H:M) <br />12/21 24:00:00 <br />Outside DB / WB / HR <br />25.4 °F / <br />19.1 °F <br />/ 5.9 gr/lb <br />Zone DB / RH / HR <br />70.0 °F / <br />8.1 % <br />/ 8.9 gr/lb <br />Time <br />Percent <br />Instant <br />Delay <br />of <br />Sensible <br />Sensible <br />Latent <br />Total <br />Total <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(Btu/h) <br />(%) <br />Roof <br />0 <br />-2,340 <br />0 <br />-2,340 <br />30.1 <br />Other Roof <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Glass <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Door <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Wall <br />0 <br />-344 <br />0 <br />-344 <br />4.4 <br />Below -Grade Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Other Wall <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Partition <br />0 <br />-2,796 <br />0 <br />-2,796 <br />36.0 <br />Exterior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Interior Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Slab <br />0 <br />-421 <br />0 <br />-421 <br />5.4 <br />Other Floor <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Infiltration <br />-1,120 <br />0 <br />0 <br />-1,169 <br />15.0 <br />Envelope Subtotal <br />-1,120 <br />-5,901 <br />0 <br />-7,070 <br />- <br />People <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Lights <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Miscellaneous Loads <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Internal Subtotal <br />0 <br />0 <br />0 <br />0 <br />- <br />RA (All Other) <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />DOA Direct to Zone <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Ceiling <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Refrigeration <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Service Water <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />HVAC Equipment Losses <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Adj Air Transfer Heat <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />Sizing Factor Correction <br />-685 <br />0 <br />0 <br />-685 <br />8.8 <br />Time Delay Correction <br />0 <br />-19 <br />0 <br />-19 <br />0.2 <br />Grand Total <br />-1,805 <br />-5,920 <br />0 <br />-7,774 <br />100.0 <br />RA Sensible (Lights) <br />0 <br />0 <br />0 <br />0 <br />- <br />Engineering Checks <br />Heating Mbh <br />-7.77 <br />Input Ventilation cfm <br />151 <br />Heating cfm <br />940 <br />Calculated Ventilation cfm <br />151 <br />Heating ACH <br />3.04 <br />Calculated Ventilation ACH <br />0.49 <br />Sec Fan cfm <br />0 <br />Number of People <br />13.51 <br />ft2/Mbh <br />-182.64 <br />People per 1000 ft2 <br />10 <br />cfm/Mbh <br />-120.93 <br />Conditioned ft2 <br />1,419.8 <br />Btu/h-ft2 <br />-5.48 <br />Volume (ft3) <br />18,574.5 <br />Alternative: Primary Calculated at: Feb 28, 2024 - 12:09 PM <br />File EDWARD JONES, EVERETTE, WA.mdf TRACE 3D Plus 5.20.117 <br />name: <br />