My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett, WA IMEG #24000280.11 <br />August 21, 2024 Page 3 of 4 <br />IMEG Response: Dampers have been provided at the OA inlet, EA inlet and relief air <br />outlet of the existing energy recovery ventilator. Refer to review drawing M2 and <br />keynote 14 on drawing M2. <br />9. Energy code mechanical requirements sheet M11 <br />IMEG Response: Note that with the addition of the commissioning specifications, this <br />sheet is now sheet M12. <br />a. Page 11 of 25 — It is unclear how setback controls are being specified on sheet M2 as <br />noted. Please clarify. See C403.4.2. <br />IMEG Response: Refer to keynote 4 on drawing M2 and Mechanical Design Conditions <br />on drawing MO. Each fan coil unit is provided with a programmable thermostat and per <br />the Mechanical Design Conditions on drawing MO the setback temperatures are down to <br />550F and up to 85°F. This is in compliance with C403.4.2 and C403.4.2.1. <br />b. Page 11 of 25 — Please provide automatic start and stop, or explain why automatic start <br />and stop are "NA." See C403.4.2.3. <br />IMEG Response: This has been revised to YES on the energy compliance forms. <br />Keynote 4 on drawing M2 has been revised to indicate this requirement as part of the <br />programmable thermostat for the fan coil units. <br />c. Page 12 of 25 — It appears DDC is required per C403.4.11.1. Please revise or note the <br />exception used. <br />IMEG Response: Per Table C403.4.11.1 DDC would be required for Alterations or <br />Additions when air handling systems or fan coil units are being provided and the existing <br />air handling system(s) and fan coil(s) served the same chilled or hot water plant have <br />DDC. The existing systems do not include DDC controls and furthermore there is no <br />chilled or hot water plant. Based on this Table DDC does not appear to be required. <br />d. Page 12 of 25 - Economizers are required per C403.5. Please revise or note exception(s) <br />used. <br />IMEG Response: Exception 9 applies to this project. This project is provided with an <br />existing dedicated outdoor air system that includes energy recovery even though it is not <br />required per C403.7.6. Furthermore, this dedicated outdoor air system with energy <br />recovery does not include mechanical cooling. <br />Page 13 of 25 - It is unclear how plenums and shafts are sealed. Please clarify. See <br />C403.10.1. <br />IMEG Response: Reference on the energy compliance document has been revised to <br />drawing M4. The Ductwork Insulation Schedule has been revised to include outdoor air <br />ductwork shall be insulated with minimum R-7 insulation in accordance with Table <br />C403.10.1.1. Note that the outside air ductwork for this project is inside the conditioned <br />space and conveys less than 2800 CFM. For duct sealing refer to specification section <br />23 3000, 3.2 on drawing M9. <br />Page 13 of 25 — It is unclear how duct pressure are being specified on sheet M2 as <br />noted. Please clarify. See C403.10.2. It is unclear if high pressure duct testing is <br />required. Please clarify, note exceptions as applicable. See C403.10.2.3. <br />IMEG Response: Ductwork pressure classification is indicated in General Note 'C' on <br />drawing M2. General Note 'C' has been revised to indicate the correct code version and <br />reference section. <br />,qk <br />
The URL can be used to link to this page
Your browser does not support the video tag.