Laserfiche WebLink
,A. i rtest <br /> Roof Top Unit <br /> PROJECT: Kaiser Permanente EMCE DATE: 2/15/2024 <br /> LOCATION: Everett,WA CONTACT: Shane Moore <br /> PROJECT#: 230035 AUTHOR: Adam Hoskins <br /> Inlet-045 Waiting Area RG 14 RD 420 370 365 87 <br /> Inlet-046 Hallway RG 8 RD 100 85 90 90 <br /> Inlet-047 Clinic Tech RG 8 RD 200 185 185 93 <br /> Inlet-048 Pharmacy Lobby RG 8 RD 100 85 90 90 <br /> Inlet-049 Pharmacy RG 12 RD 310 260 300 97 <br /> Inlet-050 Pharmacy RG 12 RD 310 275 295 95 <br /> Inlet-051 Pharmacy RG 10 RD 260 225 210 81 <br /> Inlet-052 Waiting Area RG 10 RD 240 215 220 92 <br /> Inlet-053 Waiting Area RG 10 RD 240 230 230 96 <br /> Inlet-054 Waiting Area RG 10 RD 240 220 220 92 <br /> Inlet-055 Hallway RG 10 RD 210 175 160 76 <br /> Inlet-056 Testing Rm 1 RG 6 RD 120 105 110 92 <br /> Inlet-057 Testing Rm 2 RG 6 RD 120 115 110 92 <br /> Inlet-058 Testing Rm 3 RG 6 RD 120 110 110 92 <br /> Inlet-059 Hallway RG 8 RD 100 90 1 90 90 <br /> Inlet-060 1708 RG 12 RD 420 350 350 83 <br /> Inlet-061 1701 Lab RG 6 RD 90 85 85 94 <br /> Inlet-062 1701 Lab RG 8 RD 200 170 180 90 <br /> Inlet-063 1703 Station RG 6 RD 100 115 100 100 <br /> Inlet-064 1704 Station RG 6 RD 100 95 150 150 <br /> Inlet-065 Work Room Hallway RG 12 RD 200 190 210 105 <br /> Inlet-066 Work Room Hallway RG 6 RD 200 130 180 90 <br /> Inlet-067 1803A Storage RG 6 RD 75 110 70 93 <br /> Inlet-068 Imaging Entry RG 10 RD 240 210 220 92 <br /> Inlet-069 Dressing Room RG 8 RD 150 140 145 97 <br /> Inlet-070 Mammography 1 RG 10 RD 270 240 1 245 91 <br /> Inlet-071 1624 Office RG 8 RD 100 90 95 95 <br /> Inlet-072 Mammography Entry RG 6 RD 50 50 50 100 <br /> Inlet-073 Mammography 2 RG 12 RD 330 330 300 91 <br /> Inlet-074 Ultrasound 2 RG 10 RD 200 185 180 90 <br /> Inlet-075 Ultrasound 3 RG 10 RD 210 200 185 88 <br /> Inlet-076 1617 Work Room RG 10 RD 210 185 190 90 <br /> Inlet-077 Ultrasound 1 RG 10 RD 210 190 195 93 <br /> Inlet-078 Ultrasound 4 RG 8 RD 205 190 195 95 <br /> Inlet-079 Hallway RG 8 RD 155 160 140 90 <br /> Inlet-080 CT Scan Entry RG 6 RD 50 45 50 100 <br /> Inlet-081 CT Control RG 8 RD 100 95 90 90 <br /> Inlet-082 Small Storage RG 6 RD 50 50 45 90 <br /> Inlet-083 Large Storage RG 14 RD 675 655 625 93 <br /> Inlet-084 CT Scan RG 14 RD 500 670 455 91 <br /> Inlet-085 1637 Pre-Op Holding RG 12 RD 500 375 440 88 <br /> Inlet-086 1637 Pre-Op Holding RG 12 RD 340 290 310 91 <br /> Inlet-087 Hallway RG 6 RD 55 45 50 91 <br /> Inlet-088 Hallway RG 6 RD 90 35 80 89 <br /> Inlet-089 Hallway RG 8 RD 100 95 90 90 <br /> Inlet-090 Hallway RG 6 RD 210 75 90 43 <br /> Inlet-091 1646 Imaging Hallway RG 8 RD 295 215 175 59 <br /> Inlet-092 1650A Control RG 8 RD 65 40 55 85 <br /> Inlet-093 1650 Imaging 1 RG 8 RD 280 130 130 46 <br /> Inlet-094 1649 Imaging 2 RG 8 RD 315 140 155 49 <br /> Inlet-095 1649A Control RG 8 RD 50 45 45 1 90 <br /> Inlet-096 1648 Work Room RG 8 RD 275 125 140 51 <br /> Inlet-097 1647A Control RG 8 RD 55 45 45 82 <br /> Inlet-098 1647 Imaging 3 RG 8 RD 160 130 130 81 <br /> Inlet-099 CT Scan RG 15 RD 645 375 465 72 <br /> Airtest Co. LLC <br /> Preliminary TAB Report <br />